Справочник Пользователя для Mitsubishi Electronics QD75D2N

Скачать
Страница из 860
 
 
 
11 - 19 
MELSEC-Q
11   MANUAL CONTROL 
 
11.3.2 Inching operation execution procedure 
The inching operation is carried out by the following procedure. 
 
STEP 1
Preparation
Refer to
CHAPTER 5 and
Section 11.3.3.
End of control
Set the parameters. 
STEP 2
Refer to Section
11.3.4. 
STEP 3
  Write the sequence program created in STEP 1 and
  Turn ON the JOG start signal. 
STEP 4
One of the following two methods can be used. 
<Method 1>
Monitor using GX Configurator-QP.
<Method 2>
<Method 1>
Directly set (write) the parameters in the QD75 using GX 
Configurator-QP. 
<Method 2> 
Set (write) the parameters from the CPU module to the QD75 using
the sequence program (TO instruction).
STEP 5
   instruction.) 
 
  operation.
Write the sequence program to the CPU module.
Turn ON the JOG start signal of the axis to be started. 
Monitoring of the
inching operation
STEP 6
Turn OFF the JOG operation start signal that is ON.
Monitor the inching operation status. 
Forward run JOG start signal
Axis 1
Y8
Y9
YA
YB
YC
YD
Refer to
CHAPTER 6. 
Axis 3
Axis 2
Inching operation
start
Inching operation
stop
to
)
Pr.1
)
Pr.31
Set the "  Cd.16  inching movement amount".
(Control data setting)
YE
YF
Axis 4
End the inching operation after moving a workpiece
by an inching movement amount with the sequence
program created in STEP 2.
Create a sequence program in which the "JOG start 
signal" is turned ON by an inching operation start 
command. 
One of the following two methods can be used. 
 
  Using GX Developer, set the control data and create a
 
  sequence program for executing the inching
  (Set the control data in the QD75 buffer memory using the TO
  STEP 2 to the CPU module using GX Developer.
 Reverse run JOG start signal
Monitor using GX Developer. 
 
 
REMARK 
   Mechanical elements such as limit switches are considered as already installed. 
   Parameter settings work in common for all control using the QD75.