Справочник Пользователя для Mitsubishi Electronics QD75D2N

Скачать
Страница из 860
 
 
 
12 - 29 
MELSEC-Q
12   CONTROL SUB FUNCTIONS 
 
12.4.2 Torque limit function 
The "torque limit function" limits the generated torque to a value within the "torque limit 
value" setting range when the torque generated in the servomotor exceeds the "torque 
limit value".   
The "torque limit function" protects the deceleration function, limits the power of the 
operation pressing against the stopper, etc. It controls the operation so that 
unnecessary force is not applied to the load and machine.   
The QD75 does not carry out the torque limit of servo motor directly with this function. 
The torque limit command to servo amplifier is carried out by the D/A converter module. 
 
The details shown below explain about the "torque limit function".   
    [1] System configuration for carrying out the torque limit 
    [2] Relation between the torque limit function and various controls 
  [3] Control details 
  [4] Control precautions 
  [5] Setting method 
 
[1]      System configuration for carrying out the torque limit 
Carry out the torque limit in the configuration in the figure below. (The following 
modules are required.) 
  D/A converter module 
  Drive unit capable of torque limit control by analog voltage input 
 
CPU module
QD75
Drive unit 
Positioning 
control
3) Torque limit
1) Reading data 
    by the FROM 
    instruction
2) Writing data 
    by the TO 
    instruction
D/A converter module
826 Torque limit stored 
value
Buffer memory
 
1) Read out the "   Md.35   Torque limit stored value". 
2) Write the value read in 1) into the D/A converter module. 
(The value must be converted according to the specifications of D/A 
converter module.) 
3) The drive unit carries out the torque limit according to the voltage 
input from the D/A converter module. 
Fig. 12.16 Torque limit to the drive unit (axis 1)