Справочник Пользователя для Mitsubishi Electronics QD75D2N

Скачать
Страница из 860
 
 
 
14 - 3 
MELSEC-Q
14   DEDICATED INSTRUCTIONS 
 
14.3 Z.ABRST1, Z.ABRST2, Z.ABRST3, Z.ABRST4 
These dedicated instructions restore the absolute position of the designated axis. 
 
Setting 
data 
Usable device 
Internal device 
File  
register 
Link direct device J \
Intelligent 
function 
module 
U \G  
Index 
register  
Zn 
Constant 
Others 
Bit Word 
Bit Word 
K, 
(S) 
– 
 
– – 
– 
(D) 
 
 
– – – 
– 
 
Z.ABRST1
Z.ABRST1
(S)
(D)
Z.ABRST2
Z.ABRST2
(S)
(D)
Z.ABRST3
Z.ABRST3
(S)
(D)
Z.ABRST4
Z.ABRST4
(S)
(D)
[Instruction symbol]
[Execution condition]
"Un"
"Un"
"Un"
"Un"
*
1
*
1
*
1
*
1
 
*1 If the originating station is a Basic model QCPU (function version B or later), universal model QCPU, or safety CPU, "" 
(double quotation) of the first argument can be omitted. 
 
When Z.ABRST1, Z.ABRST2, Z.ABRST3, and Z.ABRST4 are common to each other, they are designated as   
" Z.ABRST  ". 
 
[Setting data] 
 
Setting data 
Setting details 
Setting side 
( 1) 
Data type
"Un" 
QD75 head I/O number 
(00 to FE: High-order two digits of I/O number expressed in three digits) 
User 
BIN 16 bits
(S) 
Head number of a device in which control data is stored 
– 
Device name
(D) 
Head number of a bit device which turns ON the operation by one scan at the 
time of completion of the instruction.   
If the instruction is completed abnormally, ((D) + 1) will also be turned ON. 
System Bit 
Note) The file register of each of the local device and the program cannot be used as a device for setting data. 
1:  The data on the setting side is as follows. 
• User 
:  Data before the execution of dedicated instructions is stored by user. 
• System  :  Data after the execution of dedicated instruction is stored by CPU module.