10   HIGH-LEVEL POSITIONING CONTROL 
 
10.4.2 Condition data setting examples 
The following shows setting examples for "condition data".   
 
(1)      Setting the device ON/OFF as a condition 
 
[Condition] Device "XC" (= Axis 1 Busy signal) is OFF 
 
 Da.15 
 
Condition target 
 Da.16 
 
Condition 
operator 
 Da.17 
 
Address 
 Da.18 
 
Parameter 1 
 Da.19 
 
Parameter 2
01
H
: Device X 
08
H
: DEV=OFF
– 
0C
H
 – 
 
(2)      Setting the numeric value stored in the "buffer memory" as a 
condition 
 
[Condition] 
The value stored in buffer memory addresses "800, 801" (= 
"   Md.20   Current feed value") is "1000" or larger. 
 
 Da.15 
 
Condition target 
 Da.16 
 
Condition 
operator 
 Da.17 
 
Address 
 Da.18 
 
Parameter 1 
 Da.19 
 
Parameter 2
04
H
: Buffer memory 
(2 words) 
04
H
 
 P1
800 1000  – 
 
(3)      Designating the axis and positioning data No. to be 
simultaneously started in "simultaneous start" 
 
[Condition] 
Simultaneously starting "axis 2 positioning data No.3". 
 
 Da.15 
 
Condition target
 Da.16 
 
Condition 
operator 
 Da.17 
 
Address 
 Da.18 
 
Parameter 1 
 Da.19 
 
Parameter 2 
05
H
: Positioning 
data No. 
20
H
: Axis 2 
designation
– 
High-order 16 
bits "0003
H
"  1 
–  1 
1: The setting value of start axis (the axis which executes positioning start) should be 
"0000
H
".