11   MANUAL CONTROL 
 
11.1 Outline of manual control   
11.1.1 Three manual control methods 
"Manual control" refers to control in which positioning data is not used, and a 
positioning operation is carried out in response to signal input from an external source.   
The three types of this "manual control" are explained below.   
 
[1]   JOG operation 
"JOG operation" is a control method in which the machine is moved by only a 
movement amount (pulses are continuously outputted while the JOG START 
signal is ON). This operation is used to move the workpiece in the direction in 
which the limit signal is ON, when the operation is stopped by turning the limit 
signal OFF to confirm the positioning system connection and obtain the 
positioning data address (Refer to Section 12.7.4 "Teaching function"). 
 
M
Movement continues while 
the JOG START signal is ON.
JOG start signal 
ON
OFF
 
Fig. 11.1 JOG operation 
 
[2]   Inching operation 
"Inching operation" is a control method in which a minute movement amount of 
pulses is output manually at 1.8ms. 
When the "inching movement amount" of the axis control data is set by JOG 
operation, the workpiece is moved by a set movement amount. (When the 
"inching movement amount" is set to "0", the operation is performed as the JOG 
operation.) 
 
M
ON
OFF
JOG start signal
Movement for pulse amount outputted in 1.8ms 
after the JOG START signal is ON
 