1. 
LIST OF ALARMS 
1.1 Operation 
Alarm 
I - 2 
 
Error No. 
Details 
Remedy 
0006 
H/W STRK END (H/W stroke end)  
The stroke end function has activated 
(the input signal is "OFF") and one of the 
axes is in the stroke end status. 
•  Move the machine manually. 
•  Check for broken wires in the stroke end 
signal wire. 
•  Check for trouble in the limit switch. 
0007 
S/W STRK END (S/W stroke end)  
The stored stroke limit I‚ II‚ IIB‚ IB or IC 
function has activated. 
•  Move it manually. 
•  If the stored stroke limit in the parameter 
is incorrectly set‚ correct it. 
0008 
Chuck/tail-stock barrier stroke end axis 
found 
The chuck/tail-stock barrier function 
turned ON‚ and an axis entered the 
stroke end state. 
•  Reset the alarm with reset‚ and move 
the machine in the reverse direction. 
0009 
Reference point return number illegal 
Return to the No. 2 reference point was 
performed before return to the No. 1 
reference point was completed. 
•  Execute No. 1 reference point return. 
0019 
Sensor signal illegal ON 
The sensor signal was already ON when 
the tool measurement mode (TLM) 
signal was validated. 
The sensor signal turned ON when there 
was no axis movement after the tool 
measurement mode (TLM) signal was 
validated. 
The sensor signal turned ON at a 
position within 100
µm from the final 
entry start position. 
•  Turn the tool measurement mode signal 
input OFF, and move the axis in a safe 
direction. 
•  The operation alarm will turn OFF even 
when the sensor signal is turned OFF. 
Note)  When the tool measurement mode 
signal input is turned OFF, the axis 
can be moved in either direction. 
Pay attention to the movement 
direction. 
0020 
Reference point return illegal 
Return to the reference point was 
performed before the coordinates had 
not been established. 
•  Execute reference point return 
0024 
Zero point return disabled during absolute 
position detection alarm 
A zero point return signal was input 
during an absolute position detection 
alarm. 
•  Reset the absolute position detection 
alarm‚ and then perform zero point 
return. 
0025 
Zero point return disabled during zero 
point initialization 
A zero point return signal was input 
during zero point initialization of the 
absolute position detection system. 
•  Complete zero point initialization‚ and 
then perform zero point return.