Справочник Пользователя для Mitsubishi Electronics E60

Скачать
Страница из 415
1. 
LIST OF ALARMS 
1.2 Stop 
Codes 
I - 12 
 
T03 BLOCK STOP 
This indicates that automatic operation stopped after executing 
one block of the program. 
Error No. 
Details 
Remedy 
0301 
SNGL BLK ON (Single block on)  
The SINGLE BLOCK switch on the 
machine operation panel is ON. 
The single block or machine lock switch 
changed. 
•  Automatic operation can be resumed by 
turning the CYCLE START switch ON. 
0302 
User macro stop 
The block stop command was issued in 
the user macro program. 
•  Automatic operation can be resumed by 
turning the CYCLE START switch ON. 
0303 
Mode change 
The automatic mode changed to another 
automatic mode. 
•  Return to the original automatic 
operation mode‚ and resume automatic 
operation by turning the CYCLE START 
switch ON. 
0304 
MDI completion 
The last block of MDI was completed. 
•  Set MDI again‚ and turn the CYCLE 
START switch ON to resume MDl 
operation. 
0305 
Block start interlock 
The interlock signal that locks the block 
start is entered. 
•  Check the sequence program. 
0306 
Block cutting start interlock 
The interlock signal that locks the block 
cutting start is entered. 
•  Check the sequence program. 
0310 
Offset change of inclined Z-axis during 
program operation 
Whether to validate the offset of the 
inclined Z-axis switched during program 
operation. 
•  Automatic operation can be restarted by 
turning ON the cycle start switch. 
 
 
T04 COLLATION STOP 
Collation stop was applied during automatic operation. 
Error No. 
Details 
Remedy 
0401 
Collation stop occurred. 
•  Automatic operation can be restarted 
with automatic start.