Справочник Пользователя для Mitsubishi Electronics E60

Скачать
Страница из 415
8. SPINDLE 
PARAMETERS 
8.3 MDS-B-SP/SPH, 
MDS-C1-SP/SPH 
II - 282 
 
No. Items 
Details 
Setting 
range 
Standard 
setting 
3457 
(PR) 
to 
3520 
(PR) 
SP257  
 
to 
SP320  
RPM 
 
 
BSD 
Motor 
constant 
(H coil) 
This parameter is valid only in the 
following two conditional cases: 
 
(a) In case that SP034 (SFNC2) bit0=1 
and SP034 (SFNC2) bit2=0 
Set the motor constants when using a 
special motor, not described in the 
SP040 (MTYP) explanation and when 
not using the coil changeover motor. 
(b) In case that SP034 (SFNC2) bit0=1 
and SP034 (SFNC2) bit2=1 
Set the motor constant of the H coil of 
the coil changeover motor. 
 
(Note) It is not allowed for the user to 
change the setting. 
0000 to 
FFFF 
HEX setting 
0000 
 
<Details for Motor constant> 
No. Items 
Details 
Setting 
range 
Standard 
setting 
3494  SP294 Kt 
Torque 
constant for 
disturbance 
observer 
Set the torque constant for disturbance 
observer. 
30-minute 
rated output
× 1000
Setting 
(0.01kg•m)=
Base speed × 1.026
× 100
 
0000 to 
FFFF 
HEX setting 
3495  SP295 GDM 
Motor 
inertia for 
disturbance 
observer 
Set the motor inertia for disturbance 
observer. 
Setting (0.001kg•m
2
)=GD
M
2
 × 1000 
0000 to 
FFFF 
HEX setting