Справочник Пользователя для Mitsubishi Electronics E60

Скачать
Страница из 415
1. 
LIST OF ALARMS 
1.9 
Computer Link Errors 
I - 42 
1.9  Computer Link Errors 
Error Message 
Error 
No. 
Details Remedy 
–4 
Communication ends with timeout. 
CNC has a 248-byte receive buffer. 
The time during which CNC receives 
248 bytes exceeds the "TIME-OUT" 
value set in the I/O device parameter.
 
1)  Set a greater timeout value in the 
input/output device parameter. 
2)  Recheck the HOST software as to 
whether or not the HOST transmits 
data in response to DC1 from CNC 
(data request). 
3)  Check whether or not start code of 
computer link parameter is set to 0. 
–10  HOST ER (CNC DR) signal is not turned 
ON. 
1)  Check whether or not the cable is 
disconnected from the connector. 
2)  Check whether or not the cable is 
broken. 
3)  Check whether or not the HOST power 
is turned ON. 
–15  Communication ends with parity H. 
1)  Recheck the HOST software as to 
whether or not the data to be 
transmitted to CNC is ISO code. 
–16  Communication ends with parity V. 
1)  Recheck the data to be transmitted to 
CNC. 
L01   
DNC ERROR 
–17  Although CNC transmits DC3 (request to 
stop data transfer) to the HOST, it 
receives data of 10 bytes or more from 
the HOST, thus terminates 
communication. 
When CNC is transmitting data to the 
HOST, it receives data of 10 bytes or 
more from the HOST. 
1)  Recheck the software as to whether or 
not the HOST stops transmitting data 
within 10 bytes after receiving DC3. 
2)  Recheck the HOST software as to 
whether or not the HOST transmits 
data such as a command or header to 
CNC during receiving a work program.