33 Extension File Register Control – FNC290 to FNC299
33.6 FNC295 – INITER / Initialize ER
33.6
FNC295 – INITER / Initialize ER
Outline
This instruction initializes extension file registers (ER) to “HFFFF” (<K-1>) in a memory cassette (flash memory) before
executing the SAVER (FNC291) instruction.
Because the INITER (FNC295) instruction is not supported in FX
3UC
 PLC earlier than Ver. 1.30, use INITR (FNC292)
instruction instead.
→ For SAVER (FNC291) instruction, refer to Section 33.2.
→ For INITR (FNC292) instruction, refer to Section 33.3.
1. Instruction format
2. Set data
3. Applicable devices
Explanation of function and operation
1. 16-bit operation (INITER and INITERP)
“n” sectors of extension file registers (ER) in a memory cassette (flash memory) with the same device number as
 are initialized to “HFFFF” (<K-1>).
Initialization is executed in sectors.
The table below shows the head device number in each sector:
Operand Type
Description
Data Type
Head device number of extension register sector with the same device number as the
extension file register to be initialized
16-bit binary
n
Number of sectors of extension file registers to be initialized
Oper-
and 
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special 
Unit
Index
Con-
stant
Real 
Number
Charac-
ter String
Pointer
X Y M T C S D .b KnX KnY KnM KnS T C D R U \G
V Z Modify K H
E
" "
P
n
Sector 
number
Head device 
number
Initialized device range
Sector 
number
Head device 
number
Initialized device range
Sector 0
R0
ER0 to ER2047
Sector 8
R16384
ER16384 to ER18431
Sector 1
R2048
ER2048 to ER4095
Sector 9
R18432
ER18432 to ER20479
Sector 2
R4096
ER4096 to ER6143
Sector 10
R20480
ER20480 to ER22527
Sector 3
R6144
ER6144 to ER8191
Sector 11
R22528
ER22528 to ER24575
Sector 4
R8192
ER8192 to ER10239
Sector 12
R24576
ER24576 to ER26623
Sector 5
R10240
ER10240 to ER12287
Sector 13
R26624
ER26624 to ER28671
Sector 6
R12288
ER12288 to ER14335
Sector 14
R28672
ER28672 to ER30719
Sector 7
R14336
ER14336 to ER16383
Sector 15
R30720
ER30720 to ER32767
P
FNC 295
INITER
Mnemonic
Operation Condition
16-bit Instruction
 5 steps
INITER
Mnemonic
Operation Condition
Continuous
Operation
32-bit Instruction

INITERP
Pulse (Single)
Operation
  S
  S
   
S
FNC295
INITERP
n
Command
input