Справочник Пользователя для Mitsubishi Electronics FX3G
853
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
Series
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC277
-F
NC2
79
79
Da
ta
Trans
fer 3
fer 3
32
FNC28
0-F
NC
289
289
H
igh-Speed
Process
ing 2
33
FNC2
90-
FNC299
FNC299
Ex
tensi
on Fi
le
le
Register C
ontrol
34
FN
C300-
FNC30
5
FX
3U
-C
F-
AD
P
35
SFC
•STL
Programming
36
Interrupt
Function
37
Sp
ec
ia
l D
evi
ce
38
E
rror Code
A
Ve
rsi
on U
p
Inform
ati
on
B
Ex
ecuti
on
T
imes
Analog Special Adapter [FX
3U
/FX
3UC
] (Refer to Subsection 37.2.19 for applicability of each analog special adapter.)
D 8260 to D 8269 1st special adapter
*1
–
–
–
*2
–
–
–
–
–
–
D 8270 to D 8279 2nd special adapter
*1
–
–
–
*2
–
–
–
–
–
–
D 8280 to D 8289 3rd special adapter
*1
–
–
–
*2
–
–
–
–
–
–
D 8290 to D 8299 4th special adapter
*1
–
–
–
*2
–
–
–
–
–
–
Analog Special Adapter [FX
3S
/FX
3G
/FX
3GC
], Analog Expansion Board [FX
3S
/FX
3G
]
(Refer to Subsection 37.2.18 for applicability of each analog special adapter and analog expansion board)
D 8260 to D 8269 1st expansion board
*3
*6
–
–
–
–
–
–
–
–
–
D 8270 to D 8279 2nd expansion board
*4*5
–
*6
–
–
–
–
–
–
–
–
–
D 8280 to D 8289 1st special adapter
*1
–
–
–
–
–
–
–
–
D 8290 to D 8299 2nd special adapter
*1*5
–
–
–
–
–
–
–
–
–
Built-in analog function [FX
3S
-30M /E -2AD] (Refer to FX
3S
Hardware Edition for details.)
[D]8270
Ch1 analog input data (0 to 1020)
*7
–
–
–
–
–
–
–
–
–
–
[D]8271
Ch2 analog input data (0 to 1020)
*7
–
–
–
–
–
–
–
–
–
–
[D]8272
Not used
–
–
–
–
–
–
–
–
–
–
–
[D]8273
–
–
–
–
–
–
–
–
–
–
–
D 8274
Averaging time for ch1 (1 to 4095)
*7
–
–
–
–
–
–
–
–
–
–
D 8275
Averaging time for ch2 (1 to 4095)
*7
–
–
–
–
–
–
–
–
–
–
[D]8276
Not used
–
–
–
–
–
–
–
–
–
–
–
[D]8277
–
–
–
–
–
–
–
–
–
–
–
[D]8278
Error status
b0: Ch1 upper over-scale detection
b1: Ch2 upper over-scale detection
b2: Not used
b3: Not used
b4: EEPROM error
b5: Averaging time setting error
b0: Ch1 upper over-scale detection
b1: Ch2 upper over-scale detection
b2: Not used
b3: Not used
b4: EEPROM error
b5: Averaging time setting error
(common ch1 and ch2)
b6 to b15: Not used
*7
–
–
–
–
–
–
–
–
–
–
[D]8279
Model code: K5
*7
–
–
–
–
–
–
–
–
–
–
*1.
Count the number of connected analog special adapter from the main unit.
*2.
Available in Ver. 1.20 or later.
*3.
BD1 connector of a FX
3G
PLC (40-point and 60-point type) or the BD connector of a FX
3G
PLC (14-point and
24-point type) and FX
3S
PLC.
*4.
Expansion board connected to the BD2 connector of a FX
3G
PLC (40-point and 60-point type).
*5.
Only to FX
3G
PLC (40-point and 60-point type) can be connected.
*6.
Available in Ver. 1.10 or later.
*7.
This function is supported only in the FX
3S
-30M /E -2AD PLC.
Number and
name
Content of register
Applicable model
FX
3S
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
1NC
FX
2N
FX