22
5.5.1 Diagram of the different mode
9
Show an off LED
Show a blinking LED
Show a lighted LED
Show a blinking LED
Show a lighted LED
CHARGER
INVERTER
AC OUT
AC IN
1
2
7
8
9
All the functions are enabled. This is the
factory setting.
factory setting.
CHARGER
INVERTER
AC OUT
AC IN
1
2
7
8
9
The inverter is disabled. Only the transfer
switch and the charger will work normally.
switch and the charger will work normally.
CHARGER
INVERTER
AC OUT
AC IN
1
2
7
8
9
Charger and transfer switch are disabled. the
inverter will work continuously even if there is
a correct AC voltage at the input
inverter will work continuously even if there is
a correct AC voltage at the input
CHARGER
INVERTER
AC OUT
AC IN
1
2
7
8
9
Inverter and charger are both disabled.
Only the transfer switch function is enabled in
input voltage and frequency is OK.
Only the transfer switch function is enabled in
input voltage and frequency is OK.
6 Maintenance
Apart from the periodic controls mentioned for the connections, the COMPACT does not need any
maintenance. Keep the appliance clean and from time to time wipe it clean with a damp cloth.
7 EC Compliance
We hereby state that the products described in this user manual meets the following standards:
EN50081 I/II, EN55014 – EN61000-2-3, IEC801 II/III/IV, LVD 73/23/EEC, EMC Dir. 89/336