5 - 18 
MELSEC-A
5   DATA USED FOR POSITIONING CONTROL 
 
5.2 List of parameters 
5.2.1 Basic parameters 1 
 
Item 
Setting value, setting range 
Default 
value 
Setting value buffer 
memory address 
Value set with peripheral 
device 
Value set with sequence 
program 
Axis 1 
Axis 2 
Pr.1  Unit setting 
0 : mm 
3 0 150 
1 : inch 
2 : degree 
3 : pulse 
Moveme
nt amount p
er pulse
 
Pr.2   
No. of pulses per 
rotation (Ap) 
(Unit : pulse) 
1 to 65535 
1 to 65535 
1 to 32767: 
  Set as a decimal 
32768 to 65535: 
  Convert into hexadecimal 
  and set 
20000 1  151 
Pr.3   
Movement amount per 
rotation (Al) 
The setting value range differs according to the " Pr.1  Unit 
setting". 
Here, the value within the [Table 1] range is set. 
 [Table 1] on right page
 
20000 2  152 
Pr.4   
Unit magnification (Am)
1 : 1-fold 
1 3 153 
10 : 10-fold 
10 
100 : 100-fold 
100 
1000 : 1000-fold 
1000 
 
 
Pr.1  Unit setting 
 
This sets the command unit for positioning control. The unit is selected from mm, 
inch, degree, pulse according to the control target. The unit for axis 1 and axis 2 
can be set independently. 
 
(Example) 
mm, inch .......  X, Y table, conveyor. (If the machine has inch specifications, set 
with an inch unit.) 
degree ...........  Rotating body. (360 degree/rotation) 
pulse ..............  X, Y table, conveyor 
 
 *  Even if the unit setting is changed, the other parameters and positioning data 
values will not change. When changing the unit, check that the parameters and 
data are within the setting range. 
Set "degree" when performing speed/position changeover control in the ABS 
mode.