5   DATA USED FOR POSITIONING CONTROL 
 
Da.13  Parameter 
 
Set the value as required for "
Da.12  Special start command". 
 
Da.12
 Special start command 
Setting value
Setting details 
Block start (Normal start) 
– 
Not used. (There is no need to set.) 
Condition start 
1 to 10 
Set the condition data No. (No. of 
"condition data" set to perform 
condition judgement) 
(For details of the condition data, refer 
to Section 5.5.) 
Wait start 
Simultaneous start 
Stop 
– 
Not used. (There is no need to set.) 
Repeated start (FOR loop) 
0 to 255 
Set the No. of repetitions. 
Repeated start (FOR condition) 
1 to 10 
Set the condition data No. (No. of 
"condition data" set to perform 
condition judgement) 
(For details of the condition data, refer 
to Section 5.5.)