Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
5 - 78 
MELSEC-A
5   DATA USED FOR POSITIONING CONTROL 
 
Da.14  Condition target 
 
Set the condition target as required for each control. 
 
Setting value 
Setting details 
01
H
 : Device X 
Set the input/output signal ON/OFF as the conditions. 
02
H
 : Device Y 
03
H
 : Buffer memory (1-word) Set the value stored in the buffer memory as the condition. 
     03
H
: The target buffer memory is "1-word (16 bits)" 
     04
H
: The target buffer memory is "2-word (32 bits)" 
04
H
 : Buffer memory (2-word)
05
H
 : Positioning data No. 
Select only for "simultaneous start". 
 
 
Da.15  Condition operator 
 
Set the condition operator as required for the "
Da.14  Condition target". 
 
Da.14  Condition target 
Setting value 
Setting details 
01
H
 :  Device X 
02
H
 :  Device Y 
07
H
 :  DEV=ON 
When the input/output signal ON/OFF is set as the 
condition, set "ON" or "OFF". 
08
H
 :  DEV=OFF 
03
H
 :  Buffer memory (1-word) 
04
H
 :  Buffer memory (2-word) 
01
H
 :  

=P1 
Set how to judge the conditions for the value (

target stored in the buffer memory. 
     
06
H
 :  

P1, P2

 
05
H
 :  Positioning data No. 
09
H
 :  Axis 1 designation 
Set the axis to start simultaneously when 
"simultaneous start" is selected. 
0A
H
 :  Axis 2 designation 
 
 
Da.16  Address 
 
Set the address as required for the " Da.14  Condition target". 
 
Da.14  Condition target 
Setting value 
Setting details 
01
H
 :  Device X 
– 
Not used. (There is no need to set.) 
02
H
 :  Device Y 
03
H
 :  Buffer memory (1-word) 
Value 
(Buffer memory address) 
Set the target "buffer memory address". 
(For 2 word, set the low-order buffer memory 
address.) 
04
H
 :  Buffer memory (2-word) 
05
H
 :  Positioning data No. 
– 
Not used. (There is no need to set.)