Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3
5 - 78
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Da.14 Condition target
Set the condition target as required for each control.
Setting value
Setting details
01
H
: Device X
Set the input/output signal ON/OFF as the conditions.
02
H
: Device Y
03
H
: Buffer memory (1-word) Set the value stored in the buffer memory as the condition.
03
H
: The target buffer memory is "1-word (16 bits)"
04
H
: The target buffer memory is "2-word (32 bits)"
04
H
: Buffer memory (2-word)
05
H
: Positioning data No.
Select only for "simultaneous start".
Da.15 Condition operator
Set the condition operator as required for the "
Da.14 Condition target".
Da.14 Condition target
Setting value
Setting details
01
H
: Device X
02
H
: Device Y
07
H
: DEV=ON
When the input/output signal ON/OFF is set as the
condition, set "ON" or "OFF".
condition, set "ON" or "OFF".
08
H
: DEV=OFF
03
H
: Buffer memory (1-word)
04
H
: Buffer memory (2-word)
01
H
:
=P1
Set how to judge the conditions for the value (
)
target stored in the buffer memory.
06
H
:
P1, P2
05
H
: Positioning data No.
09
H
: Axis 1 designation
Set the axis to start simultaneously when
"simultaneous start" is selected.
"simultaneous start" is selected.
0A
H
: Axis 2 designation
Da.16 Address
Set the address as required for the " Da.14 Condition target".
Da.14 Condition target
Setting value
Setting details
01
H
: Device X
–
Not used. (There is no need to set.)
02
H
: Device Y
03
H
: Buffer memory (1-word)
Value
(Buffer memory address)
Set the target "buffer memory address".
(For 2 word, set the low-order buffer memory
address.)
(For 2 word, set the low-order buffer memory
address.)
04
H
: Buffer memory (2-word)
05
H
: Positioning data No.
–
Not used. (There is no need to set.)