Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
6 - 28 
MELSEC-A
6   SEQUENCE PROGRAM USED FOR POSITIONING CONTROL 
 
Device name  Device 
Application 
Storage details 
Program example that 
uses device 
A Ad 
Q/QnA
Data register 
D65 
Read data (axis 1 machine feed 
value (high-order)) 
Read data (axis 1 machine feed 
value (high-order) storage (for A/Q 
(A mode) RIRD command) 
 
 
 
D70 Complete 
status 
Complete status storage 
(for A/Q (A mode) RIWT command) 
 
 
 
D71  Number of write points 
Number of write points storage 
(for A/Q (A mode) RIWT command) 
 
 
 
D72 Access 
code/attribute 
Access code/attribute storage 
(for A/Q (A mode) RIWT command) 
 
 
 
D73  Access target D75P2 buffer memory
Access target D75P2 buffer memory 
storage 
(for A/Q (A mode) RIWT command) 
 
 
 
D74  Speed limit value (low-order) 
Speed limit value (low-order) 
storage 
(for A/Q (A mode) RIWT command) 
 
 
 
D75  Speed limit value (high-order) 
Speed limit value (high-order) 
storage 
(for A/Q (A mode) RIWT command) 
 
 
 
D100  Axis 1 positioning start number 
Axis 1 positioning start number 
storage (RWwm) 
 
 
 
D101  Axis 1 override 
Axis 1 override storage (RWwm+1) 
 
D104  Axis 1 new speed value (low-order) 
Axis 1 new speed value low-order 
word storage (RWwm+4) 
 
 
 
D105  Axis 1 new speed value (high-order)
Axis 1 new speed value high-order 
word storage (RWwm+5) 
 
 
 
D106  Axis 1 JOG speed (low-order) 
Axis 1 JOG speed low-order word 
storage (RWwm+6) 
 
 
 
D107  Axis 1 JOG speed (high-order) 
Axis 1 JOG speed high-order word 
storage (RWwm+7) 
 
 
 
D205  Axis 1 error number 
Axis 1 error number (RWrn+5) 
 
D207  Axis 1 operation status 
Axis 1 operation status (RWrn+7) 
 
 
1 Not used in the program that uses the dedicated commands in the QCPU (Q mode).