7 - 5 
MELSEC-A
7   MEMORY CONFIGURATION AND DATA PROCESS 
 
7.1.2 Buffer memory area configuration 
The D75P2 buffer memory is configured of the following types of areas. 
 
Buffer memory area configuration 
Buffer memory address 
Writing 
possibility 
Axis 1 
Axis 2 
Parameter area 
Basic parameter area 
0 to 14 
150 to 164 
Possible 
Detailed parameter area 
15 to 66 
165 to 216 
Zero point return basic 
parameter area 
70 to 78 
220 to 228 
Zero point return detailed 
parameter area 
79 to 89 
229 to 239 
Monitor data area 
System monitor area 
450 to 799 
Not possible 
Axis monitor area 
800 to 899 
900 to 999 
Control data area 
System control data area 
1100 to 1149 
Possible 
Axis control data area 
1150 to 1199 
1200 to 1249 
Positioning data area (No.1 
to 100) 
Positioning data area 
1300 to 2299 
2300 to 3299 
Possible 
Positioning start information 
area (No.7000) 
Start block data area 
4300 to 4349 
4550 to 4599 
4350 to 4399 
4600 to 4649 
Condition data area 
4400 to 4499 
4650 to 4749 
Indirectly specification area 
4500 to 4549 
4750 to 4799 
PLC CPU memo area 
PLC CPU memo area 
5050 to 5099 
Possible 
Block transmission area 
Block transmission area 
5100 to 6109 
Possible 
 
   *  Use of address Nos. skipped above is prohibited. If used, the system may not operate correctly. 
      (For details of the buffer memory address, refer to appendix 13.)