Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
8 - 7 
MELSEC-A
8   ZERO POINT RETURN CONTROL 
 
 Restrictions 
 
A pulse generator with a zero point signal is required. 
When the pulse generator is not provided with a zero point signal, create a zero 
point signal with an external signal. 
 
 Precautions during operation 
 
(1)  An error "Start at zero point" (error code: 201) will occur if another machine 
zero point return is attempted after a machine zero point return completion 
when the zero point return retry function is not set ("0" is set in " Pr.50
 Zero 
point return retry"). 
(2)  Machine zero point returns carried out from the near-point dog ON position will 
start at the " Pr.49  Creep speed".  
(3)  Near-point dog must be kept ON during deceleration from the zero point return 
speed to " Pr.49  Creep speed". 
(4)  If the restart command is turned ON after machine zero point return is stopped 
upon a stop signal, an error “zero point return restart not possible” (error code: 
209) occurs.