Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
9 - 29 
MELSEC-A
9   MAIN POSITIONING CONTROL 
 
9.2.4 1-axis fixed-dimension feed control 
In "1-axis fixed-dimension feed control" ("
Da.2  Control method" = fixed-dimension 
feed 1), one motor is used to carry out fixed-dimension feed control in a set axis 
direction.  
In fixed-dimension feed control, any remainder of the movement amount designated in 
the positioning data is rounded down if less than that required for control accuracy to 
output the same amount of pulses.  
 
 Operation chart 
 
In 1-axis fixed-dimension feed control, the address (Current feed value RWrn + 0 
to 1, RWrn + 8 to 9) of the current stop position (start point address) is set to "0". 
Positioning is then carried out to a position at the end of the movement amount set 
in " Da.5  Positioning address/movement amount".  
The movement direction is determined by the movement amount sign.  
 
0
0
0
0
0
Designated movement
Positioning
start 
amount
"Current feed value (RWrn + 0 to 1, 
RWrn + 8 to 9)" is set to "0" at the 
positioning start 
 
 
 
 Reverse direction
Forward direction
Stop position
Movement direction for
a negative movement amount
Movement direction for
a positive movement amount