Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
1 - 13 
MELSEC-A
1   PRODUCT OUTLINE 
 
The following work is carried out with the processes shown on the left page. 
 
 Details 
Reference 
1) 
Understand the product functions and usage methods, the configuration devices 
and specifications required for positioning control, and design the system. 
 Chapter 1 
 Chapter 2 
 Chapter 3 
 Chapter 8 to Chapter 13 
2) 
Install the D75P2 onto the DIN rail or enclosure surface, wire the D75P2 and 
external connection devices (drive unit, etc.), and connect the D75P2 and 
peripheral devices. Check that the D75P2 operates correctly. (Single module test) 
 Chapter 4 
3) 
Using the D75P2 software package, set the parameters, positioning data, start 
block data and condition data required for the positioning control to be executed. 
 Chapter 5 
 Chapter 8 to Chapter 13 
 AD75 Software Package 
Operating Manual 
4) 
Using the GPP function software package, create the sequence program required 
for positioning operation. (When not using the AD75 software package, also create 
the sequence program for setting data.) 
 Chapter 6 
 GPP Function Software 
Package Operating Manual 
5) 
Write the parameters and positioning data, etc., created with the AD75 software 
package into the D75P2. 
 Chapter 7 
 AD75 Software Package 
Operating Manual 
6) 
Using the GPP function software package, write the created sequence program into 
the PLC CPU. (When not using the AD75 software package, also write in the 
sequence program for setting data.) 
 Chapter 7 
 GPP Function Software 
Package Operating Manual 
7) 
Carry out test operation and adjustments in the test mode to check the connection 
with the D75P2 and external connection device, and to confirm that the designated 
positioning operation is executed correctly. (Debug the set "parameters" and 
"positioning data", etc.) 
 AD75 Software Package 
Operating Manual 
8) 
Carry out test operation and adjustment to confirm that the designated positioning 
operation is executed correctly. (Debug the created sequence program. When not 
using the AD75 software package, also debug the set data. 
 GPP Function Software 
Package Operating Manual 
9) 
Actually operate the positioning operation. At this time, monitor the operation state 
as required. If an error or warning occurs, remedy. 
 Chapter 5 
 Chapter 14 
 AD75 Software Package 
Operating Manual 
 GPP Function Software 
Package Operating Manual 
10)  Service the D75P2 as required. 
 Chapter 4 
11)  Dispose of the D75P2. 
 Chapter 4