Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
12 - 2 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
12.1 Outline of auxiliary functions 
"Auxiliary functions" are functions that compensate, limit, add functions, etc., to the 
control when the main functions are executed. These auxiliary functions are executed 
by parameter settings, commands from the AD75 software package, auxiliary function 
sequence programs, etc. 
 
12.1.1 Outline of auxiliary functions 
The following table shows the types of auxiliary functions available.  
 
Auxiliary function 
Details 
Functions 
characteristic 
to machine 
zero point 
return 
Zero point return retry 
function 
This function retries the machine zero point return with the upper/lower limit 
switches during machine zero point return. This allows machine zero point 
return to be carried out even if the axis is not returned to before the near-
point dog with JOG operation, etc. 
Zero point shift function 
After returning to the machine zero point, this function offsets the position by 
the designated distance from the machine zero point position and sets that 
position as the zero point address. 
Functions that 
compensate 
control 
Backlash compensation 
function 
This function compensates the mechanical backlash. Feed pulses equivalent 
to the set backlash amount are output each time the movement direction 
changes. 
Electronic gear function 
By setting the movement amount per pulse, this function can freely change 
the machine movement amount per commanded pulse. 
When the movement amount per pulse is set, a flexible positioning system 
that matches the machine system can be structured. 
Near pass mode function 
This function suppresses the machine vibration when the speed changes 
during continuous path control in the interpolation control. 
Functions that 
limit control 
Speed limit function 
If the command speed exceeds "
Pr.7  Speed limit value" during control, 
this function limits the commanded speed to within the " Pr.7  Speed limit 
value" setting range. 
Torque limit function *
1
 
If the torque generated by the servomotor exceeds " Pr.18  Torque limit 
setting value" during control, this function limits the generated torque to 
within the " Pr.18  Torque limit setting value" setting range. 
Software stroke limit 
function 
If a command outside of the upper/lower limit stroke limit setting range, set in 
the parameters, is issued, this function will not execute positioning for that 
command. 
Hardware stroke limit 
function 
This function carries out deceleration stop with the limit switch connected to 
the D75P2 external device connection connector. 
Functions that 
change control 
details 
Speed change function 
This function changes the speed during positioning. 
Set the changed speed in the speed change buffer memory "New speed 
value (RWwm+4 to 5, RWwm+12 to 13)", and change the speed with the 
speed change request "Speed change request (RY(n+2)7, RY(n+4)7)". 
Override function 
This function changes the speed within a percentage of 1 to 300% during 
positioning. This is executed using "Positioning operation speed override 
(RWwm+1, RWwm+9)". 
Acceleration/deceleration 
time change function 
This function changes the acceleration/deceleration time during speed 
change. 
Torque change function 
This function changes the "torque limit value" during control. 
 
  *
To carry out "torque limit", the "D/A conversion module" and a "drive unit capable of the torque limit command with an 
analog voltage" must be prepared.