12 - 8 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
12.2.2 Zero point shift function  
When a machine zero point return is carried out, the zero point is normally established 
using the near-point dog, stopper, and zero point signal. However, by using the zero 
point shift function, the machine can be moved a designated movement amount from 
the position where the zero point signal was detected. A mechanically established zero 
point can then be interpreted at that point.  
The zero point shift function can be used without relation to "
Pr.45  Zero point return 
method".  
 
The details shown below explain about the "zero point shift function".  
  (1) Control details 
  (2) Setting range for the zero point shift amount  
  (3) Movement speed during zero point shift 
  (4) Precautions during control 
  (5) Setting the zero point shift function 
 
 
(1)   Control details 
The following drawing shows the operation of the zero point shift function.  
 
Machine zero point return start 
Pr.55 Zero point shift amount 
Speed selected by the " Pr. 57 
Speed designation during
zero point shift"
Pr.49  Creep speed
Shift operation carried out after
the deviation counter clear and reset. 
Pr. 46  Zero point return direction 
Near-point dog
Pr. 48 Zero point return speed 
Zero point signal 
 
Fig. 12.4 Zero point shift operation