12 - 29 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
(2)   Software stroke limit check details 
 
Check details 
Processing when 
an error occurs 
1) 
An error shall occur if the current value*
1
 is outside the software 
stroke limit range*
2
(Check "Current feed value (RWrn+0 to 1, RWrn+8 to 9)" or 
"
Md.30  Machine feed value".) 
An "axis error" will 
occur, and the 
operation will not start. 
2) 
An error shall occur if the command address is outside the 
software stroke limit range. 
(Check " Da.5  Positioning address/movement amount".) 
 
*
1
  Check whether the "Current feed value (RWrn+0 to 1, RWrn+8 to 9)" or " Md.30  Machine 
feed value" is set in " Pr.15  Software stroke limit selection".  
*
2
  Moveable range from the " Pr.13  Software stroke limit upper limit value" to the " Pr.14  
Software stroke limit lower limit value". 
 
(3)   Relation between the software stroke limit function and various 
controls 
 
Control type 
Limit 
check
Processing at check 
Zero point 
return control 
Machine zero point return control 
– 
Check not carried out. 
High-speed zero pint return control 
– 
Main 
positioning 
control 
Position 
control 
1-axis linear control 
Checks 1) and 2) in above [2] are performed. 
During position control : The machine will stop 
immediately as soon as the 
software stroke limit range is 
exceeded. 
2-axis linear interpolation control
1-axis fixed-dimension feed 
control 
 
2-axis fixed-dimension feed 
control (interpolation) 
 
2-axis circular interpolation 
control 
 
Speed control 
*
3, 4
Speed/position changeover control  
*
3, 4
Other 
control 
Current value change 
– 
When the current value is changed, an error will not 
occur even if the new address is outside the software 
stroke limit range. However, an error "start outside 
stroke limit +/–" (error code: 507/508) will occur at the 
next operation start. 
JUMP command 
– 
Check not carried out. 
Manual 
control 
JOG operation 
*
5
  Check 1) in the previous section (2) is carried out. 
The machine will carry out a deceleration stop when the 
software stroke limit range is exceeded. If the address is 
outside the software stroke limit range, the operation 
can only be started toward the moveable range after the 
error is reset. 
Manual pulse generator operation 
*
5
 
 
 : Check valid 
  :  Check only carried out at start. (If "current feed value" is set in the " Pr.15  Software stroke limit selection", the 
check will not be carried out when the  Pr.22  Current feed value is updated.) 
–  :  Check not carried out (check invalid). 
  :  Valid only when "valid" is set in the " Pr.16  Software stroke limit valid/invalid setting".  
*
3
  :  The value in "Current feed value (RWrn+0 to 1, RWrn+8 to 9)" will differ according to the " Pr.22  Current feed value 
during speed control" setting.  
*
4
  :  When the unit is "degree", the check is not performed during speed control. 
*
5
  :  When the unit is "degree", the check is not performed.