12.7.8 Indirectly specification function 
The "indirectly specification function" specifies indirectly and starts the positioning data 
No. 
The "indirectly specification function" is executed by setting the positioning data No. 1 
to 600 desired to be started to the "indirectly specification data area" and starting that 
"indirectly specification data". 
The "indirectly specification data" can be set on an "indirectly specification No. (8001 to 
8050)" basis and can be set to up to 50 pieces on an axis basis. 
 
The following details will be explained about the "indirectly specification function". 
  (1) "Indirectly specification data" setting items and setting details 
  (2) "Indirectly specification data" configuration 
  (3) Control details and setting 
 
(1)   "Indirectly specification data" setting items and setting details 
The following indicates the outline of the setting items and setting details of the 
"indirectly specification data" to be stored into the D75P2. 
 
Setting item 
Setting details 
Indirectl
y specif
ication data
 
Positioning data No. for 
indirectly specification 
No. 8001 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8001 is set as the positioning start No. and 
started. 
Positioning data No. for 
indirectly specification 
No. 8002 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8002 is set as the positioning start No. and 
started. 
Positioning data No. for 
indirectly specification 
No. 8003 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8003 is set as the positioning start No. and 
started. 
Positioning data No. for 
indirectly specification 
No. 8004 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8004 is set as the positioning start No. and 
started. 
Positioning data No. for 
indirectly specification 
No. 8005 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8005 is set as the positioning start No. and 
started. 
to to 
Positioning data No. for 
indirectly specification 
No. 8046 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8046 is set as the positioning start No. and 
started. 
Positioning data No. for 
indirectly specification 
No. 8047 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8047 is set as the positioning start No. and 
started. 
Positioning data No. for 
indirectly specification 
No. 8048 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8048 is set as the positioning start No. and 
started. 
Positioning data No. for 
indirectly specification 
No. 8049 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8049 is set as the positioning start No. and 
started. 
Positioning data No. for 
indirectly specification 
No. 8050 
Set the positioning data No. (1 to 600) whose execution will 
be started when 8050 is set as the positioning start No. and 
started.