13 - 6 
MELSEC-A
13   COMMON FUNCTIONS 
 
(2)   Precautions during control 
 
(a)  Data can only be written to the flash ROM when the remote station READY 
signal [RX(n+7)B] is OFF.   
 
(b)  Writing to the flash ROM can be executed up to 100,000 times.   
(Writing to the flash ROM will become impossible after 100,000 times.)   
 
(c)  During execution of a flash ROM write request, a transient transmission 
request such as the dedicated command (RIRD, RIWT) cannot be accepted. 
A "response error" (error code: B404) will occur on the master station side if 
a transient transmission request is executed during execution of a flash 
ROM write request. 
If there is a possibility that a transient transmission request may be executed 
during execution of a flash ROM write request, create a sequence program 
so that a transient transmission request will be executed again at occurrence 
of a response error. 
(The processing time necessary for normal completion of flash ROM write is 
a maximum of 35s. Use this as a guideline for setting the retry count and 
response monitoring time.) 
 
Important 
 
Do not turn the power ON/OFF; reset, etc., during writing to the flash ROM. The 
flash ROM data may be corrupted. 
 
(3)      Backing up the execution data 
To use the "execution data backup function", set the data shown in the following 
table, and write it to the D75P2 using the sequence program.   
The writing to the flash ROM is carried out when the data is written to the D75P2.   
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address
Axis 1 
Axis 2 
Cd.9  
Flash ROM write 
request 
Set "1" (flash ROM write request). 
1138 
 
                 * Refer to section "5.7 List of control data" for details on the setting details. 
 
When the writing to the flash ROM is complete, "0" will be set in "
Cd.9  Flash 
ROM write request" by the D75P2.