Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
Appendix - 16 
MELSEC-A
APPENDICES 
 
Appendix 5 Connection examples with servo amplifiers manufactured by MITSUBISHI 
Electric Coporation 
For connection to a servo amplifier, dedicated cables are available. For wiring of the 
dedicated cables, refer to the manual of each dedicated cable. 
Appendix 5.1 Connection example of D75P2 and MR-H A  
 
(Differential driver (Open collector)) *
6
 
In the following diagram, connection for absolute position restoration has not been 
made. When making the connection for absolute position restoration, refer to the 
following page. 
 
 
 
*1  Assignment of the pin numbers of the connector of the D75P2 is the same for axis 1 and axis 2. 
*2  The upper limit (FLS) and lower limit (RLS) of the D75P2 are used for zero point return retry function. Set these inside the limit 
switches for the servo. 
*3  Limit switch for servo (stopping). 
*4  For details of connection, refer to the specification manual of the servo amplifier MR-H. 
*5  The distance between the controller and amplifier is indicated. The distance must be within 2m with the open collector. 
*6  Use “Logic selection for pulse output to the drive unit” specified in detailed parameter 1 to match the logic (positive or negative 
logic) between the D75P2 and the servo amplifier. The initial setting of D75P2 is a positive logic. 
*7  There is no need to wire the in-position signal. (It is output as in-position signal (RX(n+1)4, RX(n+4)4) but it is not used for internal 
processes of the D75P2.) 
REMARK 
The AD75C20SNH cable (for differential driver) can be used for the connection between the D75P2 and MR-H A. 
(Refer to section "2.2 List of configuration devices.")