Trouble type 
Questions/Trouble 
Remedy 
No.
Acceleration/decelerat
ion time 
How can the deceleration stop 
time during stopping be shortened 
using the hardware stroke limit? 
Set "1: Sudden stop" in the "
Pr.38     Stop group 1 
sudden stop selection", and reduce the setting value of 
" Pr.37   Sudden stop deceleration time". 
11
The motor does not operate at 
"60000ms" although the 
acceleration/deceleration time is 
set to "60000ms". 
The value set for the acceleration/deceleration time is the 
time required for the machine to accelerate from speed 
"0" to the value set in " Pr.7   Speed limit value". 
Because of that, the acceleration/deceleration time will 
also be shorter than "60000ms" if the command speed 
value is smaller than the " Pr.7   Speed limit value". 
(Refer to the explanation for  Pr.8  for details.) 
12
Can each acceleration/ 
deceleration time be individually 
set to trapezoidal or S-curve 
acceleration/deceleration? 
The trapezoidal and S-curve acceleration/deceleration 
processing is a common setting for all 
acceleration/deceleration times, so individual setting is not 
possible. 
(Refer to the section "12.7.7 Acceleration/deceleration 
process function".) 
13
The machine starts and stops 
suddenly when carrying out JOG 
operations and positioning 
operations.  
(Using an MR-J2S servo 
amplifier.) 
Review the parameter settings for acceleration/ 
deceleration time, speed limit value, JOG speed limit 
value, JOG acceleration/deceleration time, etc. 
14
How can a value higher than 
"65536ms" be set in the 
acceleration/deceleration time? 
A value up to "8388608ms" can be set when the " Pr.25  
Size selection for acceleration/deceleration time" is set to 
"1". 
15
Simplified absolute 
position detection 
system 
Are simplified absolute position 
detection system possible in the 
D75P2 models? 
They are possible if the models are used in combination 
with a Mitsubishi "AC Servo". 
(Refer to the "AC servo User's Manual" for details.) 
16
Positional deviation 
The physical position deviates 
from the commanded position, 
although the positioning is 
complete (and the monitored 
current position is correct). 
If the deviation counter value is not "0", the servo side is 
still moving. 
Increase the torque. 
17
When positioning to "6300mm" is 
commanded with 1-axis direct 
control (ABS type), the machine 
position is "6299mm" when the 
positioning is complete. 
Depending on the "Movement amount per pulse" setting, 
the positioning may be insufficient by the error amount 
when positioning is attempted to an address for which the 
No. of pulses was generated. This is because the 
movement is controlled so as not to exceed the 
designated address when the error amount movement 
amount is generated to the D75P2. 
In this situation, adjust the "Movement amount per pulse" 
setting so the positioning completes at the correct 
position. 
18
Electronic gear 
A setting of "1
m = 1pulse" is 
required in the following system. 
  Ball screw pitch = 10mm 
  No. of feedback pulses = 
8192 pulse 
In this case, the following values will result. 
 
No. of pulses per rotation = 8192 
 
Movement amount per rotation = 10000 
 
Unit magnification = 10 
Therefore, the "Movement amount per pulse" will become 
"1.2207
m".  
This value is fixed by the machine system, so it cannot be 
changed.  
Thus, the setting "1
m = 1 pulse " cannot be achieved. 
19