Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3

Скачать
Страница из 666
 
 
 
Appendix - 54 
MELSEC-A
APPENDICES 
 
Trouble type 
Questions/Trouble 
Remedy 
No.
Error/warning 
Error 997 (speed selection at zero 
point shift error) occurred. What 
does "OPR" mean? 
"OPR" stands for "Original Position Return", or in other 
words, a zero point return. 
53
Error 938 (backlash compensation 
amount error 2) occurs even when 
the backlash compensation value 
is set to "1". 
          0 
 
Backlash compensation value 
 
  255 
54
Movement amount per pulse 
Setting is not possible if the above equation is not 
satisfied.  
Adjust by setting "
Pr.4   Unit magnification" to 10-fold 
(or 100-fold, or 1000-fold), and setting " Pr.3  
Movement amount per rotation" to 1/10 (or 1/100, or 
1/1000). 
When a JOG operation is 
attempted, errors such as error 104 
(hardware stroke limit+) or error 105 
(hardware stroke limit –) occur and 
the machine does not move. 
The hardware stroke limit wiring has probably not been 
carried out.   
Refer to section "12.4.4 Hardware stroke limit function" for 
details, and wire accordingly. 
55
Error 971 (tracking control mode 
error) occurs. What could be 
causing the error? 
A value besides "0" or "1" may be set in the " Pr.44  
Near pass mode selection for path control". 
Review the set sequence program, and reset the correct 
parameters. 
56
Error 997 (speed selection at zero 
point shift error) appears when the 
remote station READY signal 
[RX(n+7)B] turns from OFF to ON.
A value besides "0" or "1" may be set in the " Pr.57  
Speed designation during zero point shift". 
Review the set sequence program, and reset the correct 
parameters. 
57
When the start signal was turned 
ON immediately after the stop 
signal ON, warning 100 (start 
during operation) was detected, 
and the start was ignored. 
The D75P2 starts the deceleration stop process when the 
stop signal ON is detected. Thus, the machine interprets 
that "positioning is still being executed" immediately after 
the stop signal ON. Even if the start signal is turned ON at 
that time, the start request will be ignored and warning 
100 will occur. 
58
Does warning 500 (deceleration 
and stop speed change) occur 
only during "stop deceleration" and 
"automatically deceleration"? 
Is there any problem if the 
operation is continued in that state 
without resetting the error? 
The warning occurs only at those times mentioned at the 
left. Because this is a warning, there is no problem if the 
operation can be continued without resetting the error.   
(When the speed is changed using the override, the new 
value will not be reflected on the data being executed, but 
will be reflected from the next start.) 
59
Positioning complete 
signal 
Position control was performed but 
positioning complete signal does 
not turn ON. 
Positioning may not have been completed normally due to 
occurrence of a stop cause. 
Check the axis monitor "Axis operation status (RWrn+7, 
RWrn+15)" after the BUSY signal has turned OFF. 
During stop: The stop signal has turned ON during 
positioning. Check the condition under which 
the stop signal (Y stop, external stop) turns 
ON. 
During error occurrence:   
An error occurred during positioning. Confirm 
the error occurrence cause from "Axis error 
No. (RWrn+5, RWrn+13). 
60
The setting of detailed parameter 2 "Positioning 
completion signal output time" is 0 or shorter than the 
scan time. 
Set the time that can be detected securely in the 
sequence program. 
61