Справочник Пользователя для Mitsubishi Electronics AJ65BT-D75P2-S3
3 - 30
MELSEC-A
3 SPECIFICATIONS AND FUNCTIONS
Storage item
Storage details
Axis warning No.
At axis warning detection, the warning code corresponding to the warning definition
is stored.
• The latest warning code is always stored. (When a new axis warning occurs, the
is stored.
• The latest warning code is always stored. (When a new axis warning occurs, the
warning code is overwritten.)
• When warning reset [RY(n+2)4, RY(n+4)4] is turned ON, the axis warning No. is
cleared (set to 0).
Axis operation status
The operation status of the axis is stored.