Справочник Пользователя для Mitsubishi Electronics C64
3. I/O Parameters
3.2 I/O Device Parameters
10
3.2 I/O Device Parameters
Parameters for up to five types of input/output devices can be set in DEV <0> to <4>.
(Note) The parameters are set for each device.
9101 ~
Set the same settings for device 0.
9201 ~
Set the same settings for device 1.
9301 ~
Set the same settings for device 2.
9401 ~
Set the same settings for device 3.
9501 ~
Set the same settings for device 4.
#
Item
Contents
Setting range (unit)
9101
9201
9301
9401
9501
9201
9301
9401
9501
DEVICE NAME 0
DEVICE NAME 1
DEVICE NAME 2
DEVICE NAME 3
DEVICE NAME 4
DEVICE NAME 1
DEVICE NAME 2
DEVICE NAME 3
DEVICE NAME 4
Set the device name corresponding to the device
No.
Set a simple name for quick identification.
No.
Set a simple name for quick identification.
Use alphabet
characters‚ numerals
and symbols to set a
name within 3
characters.
characters‚ numerals
and symbols to set a
name within 3
characters.
9102
9202
9302
9402
9502
9202
9302
9402
9502
BAUD RATE
Set the serial communication speed.
1: 9600 (bps)
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 150
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 150
9103
9203
9303
9403
9503
9203
9303
9403
9503
STOP BIT
Set the stop bit length used in the start-stop system. 1: 1 (bit)
2: 1.5
3: 2
3: 2
9104
9204
9304
9404
9504
9204
9304
9404
9504
PARITY CHECK
Specify whether to add the parity check bit to the
data during communication.
data during communication.
0: Parity bit not added
1: Parity bit added
1: Parity bit added
9105
9205
9305
9405
9505
9205
9305
9405
9505
EVEN PARITY
Specify the odd or even parity when it is added to
the data.
the data.
0: Odd parity
1: Even parity
1: Even parity
9106
9206
9306
9406
9506
9206
9306
9406
9506
CHR. LENGTH
Set the length of the data bit.
0: 5 (bit)
1: 6
2: 7
3: 8
1: 6
2: 7
3: 8