Справочник Пользователя для GTO GP-SW050

Скачать
Страница из 37
22
output connections
Note: 
 
•  Maximum rating for all relay outputs are 24Vac/dc, 1 Amp.
•  All relay outputs are dry contact (no voltage) switching.
•  All outputs have corresponding LED indicator for diagnostic purposes.
 
  The corresponding LED indicator will be lit when its relay is activated.
1. 
CLOSED 1
 and 
CLOSED 2
: At closed limit relay output.
•  These two (2) terminals are shorted when gate is at the closed limit.
2. 
RUN 1
 and 
RUN 2
:  Gate moving relay output.
•  These two (2) terminals are shorted whenever the gate is moving/running.
3. 
LOCK COM
 and 
LOCK N.O. / LOCK N.C.
:  Lock relay output
•  This relay output is designed for use with either mechanical or mag-lock device. The relay is
 
  activated (releasing the lock) during the first and the last 2-4 seconds of gate running.
 
 
Example A: Mag-Lock Connection: Use
LOCK COM
 and 
LOCK NC
terminals. The diagram below is for a  
   
typical mag-lock connection. Refer to the mag-lock manual for detailed operations.
 
Example B: For locks that are energized to release: Use
LOCK COM
 and 
LOCK NO
 terminals.
Lock Coil or Controller
24vDC Max, 1Amp Max
LOCK
RUNNING
CLOSED
LED11
LED10
LED09
REL
AY OUTPUT
S
LOCK N.C.
LOCK COM
LOCK N.O.
RUN 1
RUN 2
CLOSED 1
CLOSED 2
Example B
To positive (+) terminal of
Lock power supply
To negative (-) terminal of
Lock power supply
Mag Lock
24vDC Max, 1 Amp Max
LOCK
RUNNING
CLOSED
LED11
LED10
LED09
REL
AY OUTPUT
S
LOCK N.C.
LOCK COM
LOCK N.O.
RUN 1
RUN 2
CLOSED 1
CLOSED 2
To negative (-) terminal of
mag-lock power supply
To positive (+) terminal of
mag-lock power supply
Example A
RUNNING
CLOSED
LED10
LED09
REL
AY OUTPUT
S
LOCK N.C.
LOCK COM
LOCK N.O.
RUN 1
RUN 2
CLOSED 1
CLOSED 2