Справочник Пользователя для GTO R4854 01

Скачать
Страница из 40
  GTO 4000XLS Instruction Manual © 01.10.12  
15
RED wire to POSITIVE (+) terminal
BLACK wire to NEGATIVE () terminal
RED
BLACK
Step 2 
IMPORTANT: Connect the BLACK battery wire to the NEGATIVE (–) 
battery terminal. Connect the RED battery wire to the POSITIVE (+)
terminal. Reverse connection of battery wires will damage the 
control board
Step 3
Plug the transformer 
into the electrical outlet. (Use of a surge protector with the 
transformer is strongly recommended.) IMPORTANT: This is a 
class II indoor transformer; if using transformer outdoors be sure 
to enclose it in a weatherproof case.
Control Board Settings
Step 1
Power switch is on, gate 
is in the OPEN position, 
operator arm 
fully retracted.
Step 2
Press the transmitter to 
activate operator arm.  
The gate will begin 
to CLOSE.
Step 3
When the gate reaches 
the desired CLOSED 
position, press 
the transmitter 
to stop the gate.
Learn Master
Limit Button
1  2  3  4
ON 
DIP
STATUS
LEARN  RMT
LEARN
MAST  LIMIT 
LEARN
2ND  LIMIT 
S3
S4
S2
SOFT  START  OFF
WARNING       OFF
OPEN                PULL
SLV    OPEN     DLY.
MODE1               OFF
MODE2               OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
AUTO CLOSE  TIME 
STALL   FORCE
Step 4
With the gate at the 
correct position, 
program the closed 
limit setting by 
pressing and holding 
LEARN MAST LIMIT.
Gate in 
OPEN 
Postion
Gate 
Closing
Gate 
Closed
Gate in 
OPEN 
Postion
Control
Box
Control
Box
Control
Box
ON/OFF Switch
ON/OFF
Control
Box
Step 5
Press the transmitter 
again to allow the gate 
to return to 
the fully OPEN 
position.
The gate closed position is now programmed.   
If you make a mistake and set the limit at the 
wrong position:  press your transmitter to return 
the gate to the fully opened position, then press 
and hold the LEARN MAST LIMIT button for 5 
seconds. This will clear the memory for the closed 
limit position. Repeat Steps 1-5.
Set Closed Position Limit (for Pull-To-Open Applications)