11. CHANGING SPECIAL FUNCTION AND USING THE MEMORY SWITCHES
BAS-341F, 342F
46
Memory switches (00 - 0F)
Switch No.
When ON
memo-00
When moving to the home position, the feed plate moves in the order X        Y and the start position
moves in the order Y        X.
memo-01
When moving to the home position, the feed plate moves in the order Y        X and the start position
moves in the order X      Y.
memo-02
The forward position becomes the home position, and movement is in the order Y        X and
X    Y.
Use when there is an obstacle at the center of the work clamp.
memo-03
Eject device operates. (Eject device is available by special order.)
memo-04
Needle stops in up position during emergency stop. (Needle normally stops in down position.)
memo-05
When sewing is finished, the feed plate moves via the machine home position to the start position.
memo-06
After the final stitch, the work clamp rises and then the feed plate returns to the start position.
memo-07
Intermittent work clamp is not used (does not rise).
memo-08
When using an inner clamping device, the clamping presser is ON for 1/4 and OFF for 3/4 of the
pattern. (Inner clamping device is available as an option.)
memo-09
Changes the wiper to air drive. (Air wiper is availabe as an option.)
memo-0A
Jog feeding becomes faster during programming.
memo-0b
ON when a two-stage tensioner is used. (Two-stage tensioner is available as an option.)
memo-0c
Single-pedal operation by means of two-stage work clamp switches. DIP switch A-2 is ON
memo-0d
Clearing the emergency stop switch action is carried out using the STEP BACK switch.
memo-0E
Test feeding is carried out at the same speed as normal sewing. (For checking feed operation)
memo-0F
After sewing is finished, the work clamp automatically opens and closes once. (practice operation)
If memo-0E is ON, the work clamp opens and closes twice.