 ESG SERIES • GAS INSTALLATION MANUAL • 14.
INSTALLATION
MOBILE EQUIPMENT RESTRAINT
The gas Combitherm must use a connector that 
complies with The Standard for Connectors for 
Movable Gas Appliances
, ANSI Z21.69 CSA 6.16 and 
addenda Z21.69a-1989. A quick disconnect devise 
must be installed to comply with The Standard for 
Quick Disconnect Devices for Use with Gas Fuel

ANSI Z21 CSA 6.9.
Adequate means must be provided to limit the 
movement of this appliance. Limitation of movement 
must be made without depending on the connector, 
the quick disconnect device, nor the associated 
piping designed to limit appliance movement. If it 
becomes necessary to disconnect the restraint, it must 
be reconnected immediately following the return of 
the appliance to its original position.
1.
   Install a manual gas shut-off valve along with an 
approved disconnect device.
2
.   Install an A.G.A. certified, heavy-duty connector 
that complies with ANSI Z 21.69 or  
CAN 1-6.10m88 along with a quick-disconnect 
device in compliance with ANSI Z21.41 or  
CAN 1-6.9m70. Connectors must be installed 
with a cable restraint to prevent excessive tension 
from being placed on the connector.
    W A R N I N G
RISK OF ELECTRIC SHOCK.
Appliance must be secured 
to building structure.