Recommended Specifications 
(for trade reference only)
Water heater(s) shall be 
Induced Draft
model
________________, manufactured by RHEEM-RUUD,
having gas input of __________ Btu/hr. and a recovery rate
of _____________ GPH at a 100°F temperature rise when
tested and certified at ____________ thermal efficiency.
Water heater(s) shall have a storage capacity of _________
gallons. Water heater(s) shall have the CSA seal of certifica-
tion and supplied with a factory installed AGA/ASME rated
temperature and pressure relief valve. Tank(s) shall be
furnished with a tube bundle having a double coating of high
temperature porcelain enamel and furnished with magnesium
anode rods rigidly supported. Water heater(s) shall meet or
exceed the thermal efficiency and standby loss requirements
of ASHRAE. Tanks shall have a working pressure rating of
150 psi, and shall be completely factory assembled, including
a pressure regulator properly adjusted for operation on
___________ gas with stainless steel burners. Controls will
be arranged for safety shutoff in event of pilot failure. Water
heater(s) with inputs less than 360,000 Btu/hr. shall have top, front and rear side inlet/outlet water connections.
Water heater(s) shall be covered by a three year limited warranty against tank leaks.
• Add for ASME construction –
Water heater(s) shall be constructed in accordance with the requirements of the 
ASME Boiler and Pressure Vessel Code, Section IV Part HLW.
Limited Warranty
This product features a three year limited warranty against tank leaks. Please refer to 
Commercial Warranty Information brochure for complete warranty information.
MODEL
TANK CAPACITY
INPUT BTU/HR.
TEMP.
5
10
15
20
30
45
60
120
180 MIN. TO REC.
NUMBER GALS.
LITERS
NAT. 
& L.P.
RISE
UNITS
Min.
Min. Min.
Min.
Min. Min. Min.
Min. Min.
CONTENTS
GD100-250(A)
100
379
250,000
100°F
GAL.
90
110
131
151
191
252
312
555
797
25
37.7°C
LTR.
341
418
494
571
724
953
1183
2100
3018
GD100-270(A)
100
379
270,000
100°F
GAL.
92
114
135
157
201
266
332
594
855
23
37.7°C
LTR.
348
430
513
595
761
1008
1256
2247
3238
GD100-310(A)
100
379
310,000
100°F
GAL.
95
120
145
170
220
295
371
671
972
20
37.7°C
LTR.
360
455
549
644
834
1118
1403
2541
3679
GD100-360(A)
100
246
360,000
100°F
GAL.
99
128
157
186
245
332
419
768
1117
17
37.7°C
LTR.
375
485
596
706
927
1258
1588
2911
4234
MAXIMUM DELIVERY 
In U.S. Gallons and Liters. (Includes useable storage and recovery for indicated times.)
Induced Draft Gas continued.
MODEL
INPUT BTU/HR.
THERMAL
40°F
50°F
60°F
70°F
80°F
90°F 100°F 110°F 120°F 130°F 140°F
NUMBER
NATURAL & L.P.
EFFICIENCY
UNITS
22°C
28°C
33°C
39°C
45°C
50°C
56°C
61°C
67°C
72°C
78°C
GD100-250(A)
250,000
80%
GPH
606
485
404
346
303
269
242
220
202
186
173
LPH
2294
1835
1529
1311
1147
1020
918
834
765
706
655
GD100-270(A)
270,000
80%
GPH
655
524
436
374
327
291
262
238
218
201
187
LPH
2478
1982
1652
1416
1239
1101
991
901
826
762
708
GD100-310(A)
310,000
80%
GPH
752
601
501
429
376
334
301
273
251
231
215
LPH
2845
2276
1896
1626
1422
1264
1138
1034
948
875
813
GD100-360(A)
360,000
80%
GPH
873
698
582
499
436
388
349
317
291
269
249
LPH
3304
2643
2202
1888
1652
1468
1321
1201
1101
1016
944
Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. Recovery rate shown on the rating plate (75%) thermal efficiency in accordance 
with ANSI Z21.10.3 labeling requirements. (A) indicates available ASME model.
RECOVERY CAPACITIES 
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises.
WATER CONNECTIONS
APPROXIMATE
MODEL
TOP
FRONT
REAR
SHIPPING WEIGHT
NUMBER
UNITS
A
B
C
D E F G H
IN/OUT
SIDE
SIDE
STD.
ASME
GD100-250(A)
inches
73-1/2
66-3/4
30-1/4
23-1/4
6
57-1/2
3/4
23
1-1/2
2
2
795 lbs.
835 lbs.
mm
1867
1696
768
591
152
1460
19
584
38
51
51
360 kgs.
378 kgs.
GD100-270(A)
inches
73-1/2
66-3/4
30-1/4
23-1/4
6
57-1/2
3/4
23
1-1/2
2
2
795 lbs.
835 lbs.
mm
1867
1696
768
591
152
1460
19
584
38
51
51
360 kgs.
378 kgs.
GD100-310(A)
inches
73-1/2
66-3/4
30-1/4
23-1/4
6
57-1/2
3/4
23
1-1/2
2
2
795 lbs.
835 lbs.
mm
1867
1696
768
591
152
1460
19
584
38
51
51
360 kgs.
378 kgs.
GD100-360(A)
inches
73-1/2
66-3/4
30-1/4
23-1/4
6
57-1/2
3/4
23
1-1/2
2
2
795 lbs.
835 lbs.
mm
1867
1696
768
591
152
1460
19
584
38
51
51
360 kgs.
378 kgs.
All models require a 120V /3 amp power source. (A) suffix indicates ASME tank construction available.
DIMENSIONAL INFORMATION 
All Dimensions Shown in English and Metric.
C
H
E
A
B
F
D
OUTLET
TOP
INLET
TOP
OUTLET
FRONT SIDE
OUTLET
REAR SIDE
SYSTEM
SENTINEL
T&P
INLET
FRONT SIDE
INLET
REAR SIDE
G
7"
(178mm)
1
1
12
25
25
305
1
1
12
25
25
305
1
1
12
25
25
305
1
1
12
25
25
305
GD100-250(A)
inches
mm
GD100-270(A)
inches
mm
GD100-310(A)
inches
mm
GD100-360(A)
inches
mm
CLEARANCES TO COMBUSTIBLES
MODEL
NUMBER
UNITS
SIDE
REAR
TOP
Allow a minimum of 18" (457mm) front clearance for servicing.
C O M M E R C I A L
W A T E R   H E A T E R S
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
Rheem Canada Ltd./Ltée,128 Barton Street West, Hamilton, Ontario L8N 3P3
P R I N T E D   I N   U . S . A .
1 1 / 0 6   W P
F O R M   N O . R R 1 0 2 C - 9
In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.