CONNECTIONS – PLUMBING 
 
CONNECTION SIZES 
 Rheemglas, 
Optima 
RheemPlus 
• 
Hot water connection: 
RP ¾/20 
G ¾ B 
• 
Cold water connection: 
RP ¾/20 
G ¾ B 
• 
Relief valve connection: 
RP ½/15 
RP ½/15 
 
All plumbing work must be carried out by a qualified person and in accordance 
with the Plumbing Standard AS/NZS 3500.4 and local authority requirements. 
 
WATER INLET AND OUTLET 
All pipe work must be cleared of foreign matter before connection and purged 
before attempting to operate the water heater. All olive compression fittings 
must use brass or copper olives. Use thread sealing tape or approved thread 
sealant on all fittings. 
 
An isolation valve and non-return 
valve must be installed on the cold 
water line to the water heater. An 
acceptable arrangement is shown in 
the diagram. Refer also to 
 on page 17 and to 
 
A disconnection union must always 
be provided at the cold water inlet 
and hot water outlet on the water 
heater to allow for disconnection of 
the water heater. 
 
This water heater has either a 
plastic dip tube or fitting liner in the 
inlet and outlet fittings (see 
diagram). These must be in place 
for the water heater to function 
properly. Do not remove or damage 
them by using heat nearby. They 
will be pushed into the correct 
position as the fitting is screwed in. 
 
 
 
 
 
 
 
 
23