Catalog No. FW02, 13W 4 Pin Twin Tube, 800 Lumens.
60°
30°
0
16
49
65
33
Report No. 3116FR
CANDLEPOWER SUMMARY
Angle
45˚
90˚
0
45
45
45
5
40
42
51
10
47
50
56
15
51
55
53
20
47
50
47
25
42
45
43
30
39
42
41
39
39
41
42
40
40
43
44
45
43
46
47
50
46
48
49
55
48
51
52
60
51
54
54
65
54
57
56
70
56
59
58
75
58
61
60
80
60
63
61
85
61
64
61
90
61
64
61
95
61
65
61
100
62
65
61
105
61
65
60
110
60
64
58
115
59
62
56
120
57
60
53
125
54
57
50
130
51
53
46
135
47
50
42
140
43
46
37
145
39
41
31
150
33
35
24
155
27
28
16
160
19
19
9
165
11
10
4
170
4
4
2
175
2
2
1
180
1
1
1
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30
38.44
4.8
6.5
0-40
64.77
8.1
10.9
0-60 146.09
18.3
24.6
0-90 325.97
40.7
55
90-120 173.56
21.7
29.3
90-130 213.56
26.7
36
90-150 258.21
32.3
36
90-180 267.22
33.4
45
0-180 593.19
74.1
100
**  Efficiency = 74.1%  ** 
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70% 
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room 
Cavity 
Ratio
0 80 80 80 80 75 75 64 64 45 45 41
1 69 64 60 56 59 52 50 44 34 30 26
2 62 54 48 43 50 40 42 34 27 23 19
3 55 46 40 34 43 32 36 27 23 18 15
4 50 40 33 28 37 26 31 22 20 14 12
5 46 36 29 23 33 22 27 18 18 12
9
6 42 32 25 20 29 18 24 16 16 10
8
7 39 28 22 17 26 16 22 13 14
9
7
8 36 26 19 15 24 14 20 12 13
8
6
9 33 23 17 13 22 12 18 10 12
7
5
10 31 21 16 12 20 11 17
9 11
6
5
Determined In Accordance With Current IES Published Procedures