Lytecaster
®
 Recessed Downlighting 
1035
Page 2 of 2 
5" Aperture Step Baffle Wall Washer Reflector Trim
Lightolier 
a Genlyte company 
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • K1007
Job Information 
Type:
LIgHTINg dATA
EXAMPLE:  Multiple units with 75W BR30 FL lamps, located  
2’ from wall and 2’ on center, provide illumination on the wall 
3’ down from the ceiling of 18 f.c. beneath and 17 f.c. between 
the fixtures.
FOOTCANdLES ON WALL FROM MULTIPLE UNITS
Footcandle values are averaged and rounded off and are based on a minimum of five units.
For fixture-to-wall distances, other than those shown, use maximum of 1 of 1 spacing (distance between fixtures not more than distance to wall) for best result.
To convert lighting data for a lower wattage incandescent lamp of the 
same type, multiply the footcandle values by the ratio of the lumens of the two lamps.
60W A19
 1
17
16
17
12
9
12
 2
18
18
18
13
11
13
 3
13
13
13
9
8
9
 4
9
9
9
6
6
6
 5
6
6
6
4
4
4
 6
4
4
4
3
3
3
 7
3
3
3
2
2
2
 8
2
2
2
1
1
1
 9
2
2
2
1
1
1
DIST
ANCE
 FROM
 CEILING
, FT
.
UNITS 2 FEET FROM WALL
2’
3’
75W BR30 FL
 1
24
23
24
16
16
16
 2
20
20
20
16
12
16
 3
18
17
18
12
12
12
 4
13
13
13
9
9
9
 5
9
9
9
7
6
7
 6
7
7
7
5
5
5
 7
5
5
5
4
4
4
 8
4
4
4
3
3
3
 9
3
3
3
3
3
3
DIST
ANCE
 FROM
 CEILING
, FT
.
UNITS 2 FEET FROM WALL
2’
3’
13W Quad Tube
 1
8
8
8
7
4
7
 2
11
11
11
8
7
8
 3
9
9
9
6
6
6
 4
6
6
6
4
4
4
 5
4
4
4
3
3
3
 6
3
3
3
2
2
2
 7
2
2
2
1
1
1
 8
1
1
1
1
1
1
 9
1
1
1
1
1
1
DIST
ANCE
 FROM
 CEILING
, FT
.
UNITS 2 FEET FROM WALL
2’
3’