Over-the-Range Microwave
EI30SM55JS
High standards of quality at Electrolux Home Products, Inc. mean 
we are constantly working to improve our products. We reserve the right 
to change specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
10200 David Taylor Drive 
Charlotte, NC 28262 
1-877-4electrolux (1-877-435-3287) 
electroluxappliances.com
CANADA
5855 Terry Fox Way 
Mississauga, ON L5V 3E4 
1-800-265-8352 
electroluxappliances.ca
EI30SM55J  09/13
© 2013 Electrolux Home Products, Inc.
30" Over-the-Range Microwave Specifications
Product Weight – 61 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 1.71 kW 
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded 
for safe operation.)
Amps @ 120 Volts = 14.3 Amps
Always consult local and national electric codes.
Grounded outlet should be located in cabinet above, with hole in base 
to route power cord. Carefully follow top template instructions for power
cord clearance when installing beneath smooth, flat cabinets.
Microwave’s ventilation system is preset to recirculate air inside with no
ducting system required. Exhausting air outside is optional, using either
vertical or horizontal ducting system. (Refer to Ducted Option
Specifications for outside ventilation.)
For safe and proper installation, microwave MUST be mounted to 
BOTH a top cabinet AND a wall, and connected to at least one wall stud.
Can NOT be installed in island or peninsula cabinet arrangements.
Cabinet bottom MUST be level to insure proper installation.
Cabinet MUST be capable of supporting a total load of 110 lbs.
Filler blocks recommended for installation when cabinet front hangs
below recessed bottom shelf.
Minimum distance of 30" required from cooking surface to bottom edge
of top cabinet.
Minimum distance of 66" required from floor to top of microwave.
Opening between cabinets MUST be 30" wide and free of obstructions.
For openings up to 36" wide, order optional 36" Filler Kit to fill in gap
between unit and cabinets.
Allow 26" minimum clearance for 90° door swing.
Ducted Option Specifications
For outside ventilation.
Exhaust duct adapter will be needed for outside ventilation, to mate 
with standard 3-1/4" x 10" rectangular duct. If round duct required,
rectangular-to-round transition adapter will be needed with no less than
6" diameter.
For most efficient airflow exhaust, use a straight run or as few elbows 
as possible with a maximum duct length of 3-1/4" x 10" rectangular or 
6" diameter round duct, not to exceed 140 equivalent feet.
For horizontal installation, be sure to allow enough space between wall
studs to accommodate exhaust.
Refer to installation instructions on web for detailed duct preparation and
converting exhaust vent blower system for exterior exhaust ventilation.
Note: For planning purposes only. Refer to Product Installation Guide 
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
36" Filler Kit: S – (PN # MWFILKTSS).