OPERATING INSTRUCTIONS
TO START
1. Check to ensure disposer is free of foreign objects.
2. Ensure power is on.
3. Push start button. Disposer motor will run and water 
will flow into the disposer.
4. Water flow will decrease to 1 GPM approximately  
30 seconds after intitial start-up if no load is  
present in disposer.
TO STOP
1. Push stop button. Disposer motor and water will stop.
2. Water may continue to flow into disposer for up to  
10 minutes, per the time set on the water shutoff 
delay timer.
NOTE: This post-flush clears the drain lines of  
food waste.
WATER SHUTOFF DELAY ADJUSTMENT
Locate the water shutoff delay at the top of the printed 
circuit board in the AS-101K (See Figure 8). Set the 
dip switches for the desired water shut off delay. Use 
the guide printed on the circuit board to set minutes of 
delay. The dip switches should be moved to match the 
filled-in areas of the guide.
NOTE: This feature is set in the manual position at the 
factory. To activate the automatic timed disposer  
shut-off, disconnect the electric power to the control 
center, then open the control center door. Locate the 
Dip Switch Module at the top of the printed circuit board 
(see Figure 8). Move the #5 dip switch from MANUAL to 
AUTOMATIC. The disposer now automatically shuts off 
10 minutes after it starts.
AQUA-SAVER ADJUSTMENT
CURRENT SENSING CONTROL SET-UP
See Figure 9.
1. Adjust the trip
 delay to mid-setting. This adjusts 
the length of the time the water runs at full flow  
after grinding is completed. Mid-setting is  
approximately 15 seconds.
2. With the disposer running at high water flow:
 
a. Adjust the trip point control to maximum 
  position, the light is not illuminated.
 
b. Turn the trip point control counterclockwise
  until the red fault light is illuminated, stop.
 
c. Turn the trip point control clockwise slowly,
  stopping immediately when the red fault light 
  is no longer illuminated. Turn slightly  
  counterclockwise incrementally with the light  
  remaining off to assure you are at the exact set  
  point. To ensure sensitivity, the trip point must  
  be set at the exact point the light becomes no  
  longer illuminated.
NOTE: Water flow will decrease after trip delay time  
setting expires.
Figure 8.
ELECTRICAL SHOCK
 • Turn off the electrical supply to the disposer before 
attempting any work on it. Use a voltmeter or  
circuit tester to ensure that power is off.
 • Installation must conform to local plumbing and 
electrical codes.
 • All control centers and disposers must be carefully 
and permanently grounded.
 • A properly fused disconnect must be installed at 
the electrical supply source for the control center.
 PERSONAL INJURY
To adjust the water shutoff delay, disconnect the  
electrical power to the control panel and open the 
control center door.
Example 1:  Dip switches 1, 2, 3, 4 pushed to the down 
position will give a 0 minute delay.
Example 2:  Dip switches 1, 3, 4 pushed to the up  
position; and dip switch 2 pushed to the 
down position will give a 10 minute delay.
AUTOMATIC TIMED DISPOSER SHUTOFF
This water saving feature allows the disposer to run for 
up to 10 minutes before it automatically shuts off and 
must be manually restarted.
Operating Instructions/Aqua-Saver Adjustment