AiR FOR COMBUSTiON AND VENTiLATiON
Continued
Figure 3 - Ventilation Air from Inside 
Building
Or
Remove
Door into
Adjoining
Room,
Option
2
Ventilation
Grills 
Into Adjoining 
Room,
Option 1
4"
Figure 4 - Ventilation Air from Outdoors
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
iNSTALLATiON
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining 
unconfined  space.  When  ventilating  to  an 
adjoining unconfined space, you must provide 
two permanent openings: one within 12" of the 
ceiling and one within 12" of the floor on the 
wall connecting the two spaces (see option 
1, Figure 3). You can also remove door into 
adjoining room (see option 2, Figure 3). Fol-
low the National Fuel Gas Code ANS Z223.1/
NFPA 54 Air for Combustion and Ventilation 
for required size of ventilation grills or ducts.
Ventilation Air From Outdoors
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling 
and one within 12" of the floor. Connect these 
items directly to the outdoors or spaces open 
to  the  outdoors. These  spaces  include  at-
tics  and  crawl  spaces.  Follow  the  National 
Fuel Gas Code ANS Z223.1/NFPA 54 Air for 
Combustion and Ventilation for required size 
of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings  for 
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering 
the attic will activate the power vent.
NOTICE:  This  firebox  in  com-
bination  with  unvented  log 
sets  are  intended  for  use  as 
supplemental  heat.  Use  along 
with  your  primary  heating 
system. Do not install them as 
your primary heat source. If you 
have a central heating system, 
you may run system’s circulat-
ing blower while using heater. 
This will help circulate the heat 
throughout  the  house.  In  the 
event  of  a  power  outage,  you 
can use unvented logs as your 
primary heat source.
 WARNING: A qualified ser-
vice person must install firebox. 
Follow all local codes.
 WARNING: Never install the 
firebox
•  in a bedroom or bathroom
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing  or  other  flammable 
objects are less than 42" from 
the front, top or sides of the 
firebox
•  in high traffic areas
•  in windy or drafty areas