Справочник Пользователя для Hoshizaki KM-1301SAH-E

Скачать
Страница из 59
23
e) Harvest Pump Timer (S4 dip switch 7)
CAUTION
Factory set for proper operation. Do not adjust. Adjustment outside of the 
factory default setting may result in damage to the icemaker.
Depending on the harvest pump timer setting, the pump motor energizes and runs 
the last 0 or 50 seconds of harvest. When the pump is on, water circulates over the 
evaporator. The water valve is open during harvest for a maximum of 6 minutes or the 
length of harvest minus 0 or 50 seconds (determined by the harvest pump timer setting), 
whichever is shorter. 
When S4 dip switch 7 is on, the pump motor is energized through the #5 pin (DBu wire) 
on the control board K1 ten-pin connector and the X1 relay (auxiliary code T-0, U-0), X10 
relay (auxiliary code U-1 and later). The #5 pin (DBu wire) is used in most applications 
to reverse the pump motor or energize the drain valve in pump-out cycles. In this 
application, it is used for the pump-out cycle (reverse rotation) as well as the harvest 
pump timer (freeze rotation). Therefore, the harvest pump timer relays are needed to 
control the pump motor direction during the pump-out and harvest cycles. See "III.B.
Wiring Diagrams."
S4 Dip Switch Setting
Pump Motor 
Time (seconds)
No. 7
ON
50
OFF
0
f) Factory Use (S4 dip switch 8)
Factory set for proper operation. Do not adjust. This must be left in the factory default 
position.
g) Freeze Timer (S4 dip switch 9 & 10)
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent possible 
freeze-up issues. Upon termination of the freeze timer, the control board initiates the 
harvest cycle. After 2 consecutive freeze timer terminations, the control board shuts down 
the icemaker. In this case, see "IV.G.3. Low Ice Production" for possible solutions. The
freeze timer is factory set, and generally no adjustment is required. Before changing this 
setting, contact Hoshizaki Technical Support at 1-800-233-1940 for recommendations.
S4 Dip Switch Setting
Time 
(minutes)
No. 9
No. 10
OFF
OFF
60
OFF
ON
50
ON
OFF
70
ON
ON
60