Справочник Пользователя для Hoshizaki KM-1301SAH-E

Скачать
Страница из 59
32
C. Performance Data
1. KM-1301SAH-E (air-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in 
bold 
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior 
notice.
70/21
1114
505
1082
491
992
450
80/27
1089
494
1039
471
924
419
90/32
1082
491
1004
455
897
407
lbs./day   kg./day
100/38
1048
475
979
444
799
362
70/21
80/27
90/32
watts
100/38
70/21
537
2.03
426
1.61
377
1.43
80/27
452
1.71
279
1.06
288
1.09
90/32
426
1.61
157
0.59
140
0.53
gal./day    m
3
/day
100/38
302
1.14
153
0.58
125
0.47
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
275
19.3
293
20.6
316
22.2
80/27
289
20.3
318
22.3
338
23.8
90/32
293
20.6
338
23.8
360
25.3
PSIG     kg/cm
2
G
100/38
297
20.9
343
24.1
380
26.7
70/21
57
4.0
58
4.1
61
4.3
80/27
58
4.1
59
4.2
64
4.5
90/32
58
4.1
60
4.2
64
4.5
PSIG     kg/cm
2
G
100/38
59
4.2
61
4.3
68
4.8
19,000  BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
35
41
35
37
40
35
38
2.1
4.8
3.1
4.0
2.9
2.1
4.2
34
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC 
CONSUMPTION
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP. 
(ºF/ºC)
50/10
70/21
90/32
1958
1964
2049
2120
2127
1900
1949
1964
39
43
44
48
2009
2069
2151
2180
HARVEST CYCLE TIME
HEAD PRESSURE
3.7
3.2
4.0
2.1
2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE