Installation
! Before placing your new appliance into operation please 
read these operating instructions carefully. It contains 
important information concerning the safe installation and 
operation of the appliance.
! Please keep these operating instructions for future 
reference. Make sure that the instructions are kept with the 
appliance if it is sold, given away or moved.
! The appliance must be installed by a qualified professional 
in accordance with the instructions provided.
! Any necessary adjustment or maintenance must be performed 
after the cooker has been disconnected from the electricity supply.
The cookers have the following technical specifications:
Category: II 2H3+
Room ventilation
The appliance may only be installed in permanently-
ventilated rooms, according to current national legislation. 
The room in which the appliance is installed must be 
ventilated adequately in order to provide as much air as is 
needed by the normal gas combustion process (the flow of 
air must not be lower than 2 m
3
/h per kW of installed power).
The air inlets, protected by grilles, should have a duct 
with an inner cross section of at least 100 cm
2
 and should 
be positioned so that they are not liable to even partial 
obstruction (see figure A).
These inlets should be enlarged by 100% - with a minimum of 
200 cm
2
 - whenever the surface of the hob is not equipped with 
a flame failure safety device. When the flow of air is provided in 
an indirect manner from adjacent rooms (see figure B), provided 
that these are not communal parts of a building, areas with 
increased fire hazards or bedrooms, the inlets should be fitted 
with a ventilation duct leading outside as described above. 
A
Examples of 
ventilation holes 
for comburant air.
 
Enlarging the ventilation slot
between window and floor.
Adjacent
Room
Room to be
Vented
A     B
! After prolonged use of the appliance, it is advisable to open 
a window or increase the speed of any fans used. 
Disposing of combustion fumes
The  efficient  disposal  of  combustion  fumes  should  be 
guaranteed using a hood which is connected to a safe 
and efficient natural suction chimney, or using an electric 
fan which begins to operate automatically every time the 
appliance is switched on (see figure).
In a chimney stack or branched flue. 
(exclusively for cooking appliances)
Directly to 
the Outside
! The liquefied petroleum gases are heavier than air and 
collect  by  the  floor,  therefore  all  rooms  containing  LPG 
cylinders must have openings leading outside so that any 
leaked gas can escape easily. LPG cylinders, therefore, 
whether partially or completely full, must not be installed or 
stored in rooms or storage areas which are below ground 
level (cellars, etc.). Only the cylinder being used should 
be stored in the room; this should also be kept well away 
from sources of heat (ovens, chimneys, stoves) which may 
cause the temperature of the cylinder to rise above 50°C.
Positioning and levelling
! The appliance may be installed alongside any cupboards 
whose height does not exceed that of the hob surface.
! Make sure that the wall in contact with the back of the appliance 
is made from a non-flammable, heat-resistant material (T 90°C).
To install the appliance correctly:
•  Place it in the kitchen, the dining room or the studio flat 
(not in the bathroom).
•  If the top of the hob is higher than the cupboards, the 
appliance must be installed at least 500 mm away from them.
HOOD
420
Min.
min.
 
65
0
 mm. with hood
min.
 
70
0
 mm. without hood
mm.
600
Min.
mm.
420
Min.
mm.
•  If  the  cooker  is  installed 
underneath a wall cabinet, there 
must be a minimum distance of 420 
mm between this cabinet and the 
top of the hob.
This distance should be increased 
to 700 mm if the wall cabinets are 
flammable (see figure).
•  Do not position blinds behind the cooker or less than 200 
mm away from its sides.
•  Any  hoods  must  be  installed  in  accordance  with  the 
instructions listed in the relevant operating manual.
Levelling
If it is necessary to level the 
appliance, screw the adjustable 
feet into the places provided on 
each corner of the base of the 
cooker (see figure).
Electrical connection
THE APPLIANCE MUST BE EARTHED
ATTENTION: This appliance has a maximum power 
exeeding 3kW; it is therefore necessary for it to be 
connected to a socket able to support a rated current higher 
than 13A (the appliance rated current is 15A). Connecting 
the supply cable to the mains electricity supply A 13. A plug 
in compliance whit BS 1362 is not suitable.
Install a standardised plug corresponding to the load indicated 
on the appliance data plate (see Technical data table). 
The appliance must be directly connected to the mains using 
an omnipolar switch with a minimum contact opening of 3 
mm installed between the appliance and the mains.