GR SERIES GAS FRYERS
Quick-Disconnect for Units on Casters
For an appliance equipped with casters:
The installation shall be made with a
connector that complies with the Standard
for Connectors for Movable Gas
Appliances, ANSI Z21.69 
or Connectors for
Moveable Gas Appliances, CAN/CGA-6.16,
and a quick-disconnect device that
complies with the Standard for Quick-
Disconnect Devices for Use with Gas Fuel,
ANSI Z21.41, 
or Quick Disconnect Devices
for Use with Gas Fuel, CANI-6.9.
When installing a quick disconnect you
must also install a means for limiting the
movement of the fryer. This device will
prevent the gas line or the quick
disconnect from being strained. The
restraining device should be attached to
the cutout on the back panel. See
illustration for location.
A Rear of Fryer
B Strain Relief Chain Connection
(Chain supplied by others)
In Australia, use only the caster supplied
by the manufacturer for the fryer device.
The fryer must be installed using a hose
assembly restraining device to limit the
movement of the appliance in accordance
with AS1869.
The fryer must be installed with a
connector (not supplied by Vulcan)
complying with the above code(s).
The fryer must be installed with restraining
means to guard against transmission of
strain to the connector. See illustration.
The fryer must be installed with the
casters provided.
If the restraint is ever to be disconnected,
first turn the gas supply OFF.
ELECTRICAL CONNECTION
Note: Only the 
  KleenScreen™ 
style fryer
requires an electrical connection.
WARNING: ELECTRICAL  AND
GROUNDING  CONNECTIONS
MUST  COMPLY  WITH  THE
NATIONAL  ELECTRICAL
CODE  AND / OR  OTHER
LOCAL  CODES.
WARNING: APPLIANCES  EQUIPPED  WITH
ELECTRICAL  SUPPLY
CORD(S)  ARE  PROVIDED
WITH  A  THREE-PRONG
GROUNDING  PLUG,  WHICH
MUST  BE  CONNECTED  TO  A
PROPERLY  GROUNDED
RECEPTACLE.
IF  THE  RECEPTACLE  IS  NOT
THE  PROPER  GROUNDING
TYPE,  CONTACT  AN
ELECTRICIAN.  DO  NOT
REMOVE  THE  GROUNDING
PRONG  FROM  THE  PLUG.
KleenScreen™ fryers are equipped with a 120-V,
60-Hz, 1-phase cord and plug.
Do not connect fryer to electrical supply until
after gas connections have been made.
LEVELING THE FRYER
Check the level of the fryer by placing a level
on top of the fryer after gas connections have
been made.
Ensure that the fryer is level front-to-back and
side-to-side in the final installed position.
If using casters, lock the wheels after unit is level.