GR SERIES GAS FRYERS
INSTALLATION
WARNING: THIS  EQUIPMENT  SHALL  BE
INSTALLED  ONLY  BY  A
LICENSED  GAS  FITTER.
Caution:
Do not use the door or its handle
to lift the fryer.
Before installing the fryer, verify that the type of
gas (natural or propane) agrees with the
specifications on the fryer data plate, which is
located on the inside of the door panel. Make sure
the fryer is configured for the proper elevation.
Record your fryer model, device, and serial
numbers for future reference in the space
provided below. This information can be found
on the fryer data plate.
Fryer Model No.: ______________________
Device: ______________________________
Serial No.: ____________________________
TOOLS NEEDED FOR INSTALLATION
Standard set of plumbing and hand tools.
AC current tester.
Gas pressure test gauge.
REQUIREMENTS FOR INSTALLATION
Electrical
Voltage – 120 AC (or 240 AC optional)
Voltage is required for KleenScreen™ only.
No Voltage for GR Free Standing Fryers.
Amps – 15 Amps
Frequency – 50/60 Hz
Gas Supply Pressure
Natural –   0.80 kPa (4" W.C.)
Propane – 2.75 kPa (10" W.C.)
WARNING: IF  INCOMING  PRESSURE
EXCEEDS  3.45 kPa (14" W.C.,
1/2" PSI),  AN  ADDITIONAL
PRESSURE  REGULATOR
MUST  BE  INSTALLED.
Checking the Gas Supply Pressure
Caution:
The fuel supply system must be
tested before the fryer is used.
If the fuel line is going to be tested at a pressure
greater than 1/2 psig (3.45 kPa), make sure that
the fryer is disconnected from the fuel line. If the
fuel line is to be tested at a pressure equal to or
less than 1/2 psig (3.45 kPa), the fryer can be
connected but the unit’s gas valve must be closed.
Clearances
Minimum clearance from combustible
construction:
6" (15 cm) from the sides of the fryer
6" (15 cm) from the back of the fryer
The fryer may be installed on combustible
floors.
Minimum clearance from noncombustible
construction:
0" from the sides of the fryer
0" from the back of the fryer.
Between the fryer and any open-top flame
units:
at least 16" (41 cm)
Allow space for servicing and operation,
such as opening the rear door to set
temperature and light the pilot.