Chapter 3: Installation
3. Installation
Because the VDSL2 PoE Ethernet Extenders are preconfigured for basic applications, you can install them quickly. Follow these
steps:
steps:
1. Connect the line interface between the units with RJ-11 cable.
2. Connect the Standard Extender to a twisted-pair Ethernet connection. Connect the PD Extender to a PoE PSE switch or
other PSE device using copper twisted-pair cable.
NOTE: Make sure that the PSE device is turned on, or the VDSL2 PoE Ethernet Extender (PD) will not work.
3. Connect the power adapter to the Standard extender and plug it in.
NOTE: The interconnecting cables should be rated for external use and appropriate for the application’s voltage, current,
anticipated temperature, flammability, and mechanical serviceability.
Table 3-1 shows the data rate and transmission distance information via 26 AWG at 6 dB.
Table 3-1. Supported data rates and transmission distances.
Downstream
Data Rate (Mbps)
Data Rate (Mbps)
Upstream
Data Rate (Mbps)
Data Rate (Mbps)
Distance
(feet)
(feet)
100
60
500
98
53
1000
90
44
1250
80
36
1500
70
27
1750
60
18
2000
48
11
2500
39
8
3000
35
3.5
3500
28
0.3
4000
NOTE: Depending on your application, you might need to change the DIP switches for optimum performance.