You can connect the PS Hub to different hubs and stacks (for example 
a stack of SuperStack II Hub 10 units), giving you flexibility when 
creating a new network, or expanding an existing network.
In order to conform with Ethernet rules, you can only have four 
repeaters in series. For a stack of more than one PS Hub, any path 
through the stack counts as going through two logical repeaters.
Each of the PS Hub’s 10BASE-T ports are internally crossed (MDIX). 
The type of cable and ports used must be correct for the connection to 
work:
You can use ‘Straight-through’ 10BASE-T cable to connect a 
crossover (MDIX) port to an uncrossed (MDI) port.
You can use ‘Crossover’ 10BASE-T cable to connect two crossover 
(MDIX) ports.
The last port (port 12 or 24) on the PS Hub can be either crossed or 
uncrossed. The MDI/MDIX switch affects the port’s state:
If the switch is IN, the port is uncrossed (MDI).
If the switch is OUT, the port is crossed (MDIX).
Figure 3-7 shows a SuperStack II Hub 10 connected to the PS Hub. 
A ‘Straight-through’ cable is used, and one of the SuperStack II Hub 10 
unit’s crossed (MDIX) ports is connected to port 24 on the PS Hub 
(note that the MDI/MDIX switch is IN, so the port is uncrossed).