Справочник Пользователя для Vulcan-Hart C24GA10

Скачать
Страница из 39
F35425 (February 2006)
Page 20 of 40
C24GA SERIES CONVECTION STEAMERS - SERVICE PROCEDURES AND ADJUSTMENTS
Striker Adjustment
1.
Reinstall the striker with the slot pointing
upwards and hand tighten nut only.
2.
Close the door to center the striker in the oval
mounting hole.
3.
Open the door and check the striker’s slot for
horizontal alignment. The slot on the striker must
be kept horizontal in order for the door latch to
catch it properly and latch.
4.
Once the proper slot alignment has been set,
hold the striker close to its base using an open
end wrench, add Loctite to the threads, then
tighten the striker nut. Be careful not to damage
the striker slot when tightening or door may not
latch properly. Do not over tighten as the striker
will begin to turn and change alignment.
5.
If door does not open easily, add shims as
necessary between striker and cabinet front.
6.
Repeat steps 2 thru 4.
DELIMING THE GENERATOR
WARNING: READ AND FOLLOW THE INSTRUC-
TIONS ON THE DELIMING MATERIAL PACKAGE.
AVOID CONTACT WITH SKIN AND EYES. WEAR
PLASTIC OR RUBBER GLOVES AND SAFETY
GOGGLES WHEN HANDLING. WASH THOR-
OUGHLY AFTER HANDLING. IF DELIMING SOLU-
TION COMES IN CONTACT WITH THE SKIN OR
EYES, RINSE THOROUGHLY WITH CLEAN WATER.
WARNING: THE STEAMER AND ITS PARTS ARE
HOT. USE CARE WHEN OPERATING, CLEANING
OR SERVICING THE STEAMER. THE COOKING
COMPARTMENT CONTAINS LIVE STEAM. STAY
CLEAR WHEN OPENING DOOR.
Items Required (not provided)
Deliming material.
Funnel.
Plastic or rubber gloves.
Safety goggles or face shield.
Measuring cup.
1 gallon container for mixing deliming solution.
Petrol-Gel Lubricant or equivalent food grade
grease for coating deliming port threads.
NOTE:
Deliming solution may cause the surface of
aluminum measuring tools to tarnish or
etch.
C24GA (Automatic Drain)
11 US GAL Capacity Steam Generator.
NOTE:
This procedure is not intended to take the
place of a water treatment program.
1.
Turn power switch off. Wait 5 minutes for steam
generator to completely drain and the drain valve
to close.
2.
Turn cooking timers to off.
3.
Prepare deliming solution according to the
instructions on the deliming material package.
Follow all manufacturers’ instructions.
4.
Remove delime port cap on top of unit and insert
funnel into delime port.
5.
Pour deliming solution into the steam generator
slowly to avoid spillage.
6.
Remove funnel from delime port then rinse port
with clean water.
7.
Lightly coat delime port threads with Petrol-Gel
then install delime port cap. Cap must be
installed and tightened securely at all times.
8.
Turn power switch on. When ready light comes
on, allow steamer to remain on for 40 minutes.
9.
After 20 minutes, turn cooking timers on for 1
minute to delime the steam tubes and nozzles.