Инструкции По Обслуживанию для Bunn G9 HD

Скачать
Страница из 16
Page 12
Relay
Location:
The relay is located on the timer bracket in the 
grinder base. The bracket can be removed by loosen-
ing the two 8-32 screws beneath the timer dial.
Test Procedure:
1.  Disconnect the grinder from the power supply.
2.  Check the voltage across the white/red and white/
green  wires  of  the  relay  coil  with  a  voltmeter 
when  the  Off/On/Start  switch  is  placed  in  the 
“START” (right) position and released.  Connect 
grinder to the power supply.  The indication must 
be:
 
(a)  120 volts ac for  two wire 120 volt models
 
(b)  240 volts ac for two wire 240 volt models 
for the approximate setting on the timer.
3.  Disconnect the grinder from the power supply.
If voltage is present as described, reconnect the 
white/red and white/green wires to the relay coil, and 
proceed to step 4.
If  voltage  is  not  present  as  described,  refer  to 
the  Wiring  Diagrams and  check  the  grinder  wiring 
harness.
4.  Remove the white/red and white/blue wires from 
the relay contacts.
5.  Check for continuity across the relay contacts 
when  the  Off/On/Start  switch  is  placed  in  the 
“START” (right) position and released. Connect  
grinder  to  the  power  supply.  Continuity  must 
be  present  for  the  approximate  setting  on  the 
timer.
6.  Disconnect the grinder from the power supply.
If continuity is present as described, reconnect the 
white/red and white/blue wires, the relay is operating 
properly.
If continuity is not present as described, replace 
the relay.
Removal and Replacement
1.  Remove all wires from the relay terminals.
2.  Remove the 6-32 screw fastening the relay to the 
timer bracket.
3.  Mount the new relay to the timer bracket and 
tighten the screw.
4.  Refer to the illustration below when reconnect-
ing the wires.
WHI/BLU to Motor L1
WHI/GRN to Timer L4
WHI/RED to Timer TL1
P610
MIN
UTE
S
BUNN-
O-M
ATI
C
P/N 
262
0-   
120
 VA
C
MIN
UTE
S
BUN
N-O
-MA
TIC
P/N
 262
0-   
120
 VA
C
P1312
 
If continuity is not present as described, replace 
the switch.
Removal and Replacement:
1. 
Remove  all  the  wires  from  the  switch  termi-
nals.
2. 
Compress the clips inside the housing and gently 
push the switch through the opening.
3. 
Push the new switch into the opening and spead 
the clips to hold the switch in the housing.
4. 
Refer to the illustration below when reconnecting 
the wires.
SERVICE (cont.)
TAN
PNK
YEL
ORA
GRN
P1318
Single set timer shown
Multi set timer (Urn/Carafe) similar
10171 121597